Compliance with national gas regulations shall be observed. Keep ventilation
openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants.
The appliance shall be stored in a room without continuously operating open flames
(for example an operating gas appliance) and ignition sources (for example an
operating electric heater).
•
•
•
•
•
WARNING FOR USING R32/R290 REFRIGERANT
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that the refrigerants may not contain an odour.
Appliance should be installed, operated and stored in a room with a floor area
according to the amount of refrigerant to be charged. For specific information on
the type of gas and the amount, please refer to the relevant label on the unit itself.
When there are differences between the lable and the manual on the Min. room
area description, the description on label shall prevail.
For R290
amount of refrigerant (kg)
5
6
7
8
9
10
Min. room area(m�)
0.0836 and 0.1045
≥
<
0.1045 and 0.1254
≥ <
0.1254 and 0.1463
≥
<
0.1463 and 0.1672
≥ <
0.1672 and 0.1881
≥
<
0.1881 and 0.2090
≥
<
amount of refrigerant (kg)
11
12
13
14
Min. room area(m�)
0.2090 and 0.2299
≥
<
0.2299 and 0.2508
≥
<
0.2508 and 0.2717
≥
<
0.2717 and 0.2926
≥ <
15 0.2926 and 0.3135
≥
<