EasyManuals Logo

Tectro TSM8 DUO User Manual

Tectro TSM8 DUO
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Don’t dispose electrical devices with household waste; deliver it to a designated collection
point. Contact the local authorities for information about places for disposal of electrical
devices. When electrical devices are dumped at landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, with all consequences for the health
of the local population. When replacing old devices it is the legal responsibility of the supplier
to collect the old device for disposal. Don’t throw batteries into fire. They can explode or leak
hazardous fluids. When you replace or dispose the remote control, remove the batteries and
dispose them according the legislation applicable. They are harmful to the environment.
Environmental info: This device contains fluorinated greenhouse gases, as stated in the Kyoto protocol. The
equipment may be repaired or dismantled only by professional, trained personal.
This device contains refrigerant R410A, the amount is indicated in the table above. Don’t let R410A escape
into the atmosphere: R410A is a fluorinated greenhouse gas with greenhouse gas effect (GWP) = 1975.
Internet:
In order to provide a better service, you can download the latest version of the user, installation, or service
manual at www.qlima.com.
J SPECIFICATIONS
Model TSM 8 DUO - outdoor TSM 8 MULTI - outdoor TSM 825 DUO - indoor
TSM 832 DUO -
indoor
Air conditioner type Multi split DC Inverter Multi split DC Inverter Multi split DC Inverter Multi split DC Inverter
Cooling capacity* W 5200 (1230 - 5860) 6150 (2800 - 6600) 2600 (1000 - 3100)
3500 (1050 - 3700)
EE rating cooling* A++ A++ A++
A++
SEER* 6.1 6.1 6.1
6.1
Heating capacity* W 5860 (1290 - 6280) 6600 (2450 - 6900) 2600 (1000 - 3800)
3500 (1050 - 4500)
EE rating heating* A+ A+ A+
A+
SCOP* 4.0 4.0 4.0
4.0
Dehumidifying capacity ** / *** l / 24 h 24
28.8
Power consumption cooling kW 1.5 1.88 0.04
0.04
Power consumption heating kW 1.49 1.71 0.04
0.04
Yearly power consumption cooling / heating kWh 298 / 1637 352 / 2098 149 / 910
200 / 1225
Power input V / Hz / Ph
220-240 / 50 / 1 220-240 / 50 / 1 220-240~ / 50 / 1
220-240~ / 50 / 1
Current (nom.) cooling / heating A 6.8 / 6.7 8.5 / 7.8 0.2 / 0.2
0.2 / 0.2
Max. current A 8.4
11
Air flow ** m3/h 650
680
For rooms from - to ** m3 140 - 185 200 - 270 60 - 85
80 - 100
Suited for regions W / A / C
W / A / C W / A / C W / A / C W / A / C
Fan speeds
3 3
Compressor type Rotary Rotary Rotary Rotary
Thermostatic range °C 16 - 31
16 - 31
Operating range
-15 - 53 -15 - 68
Manual / mechanical / electronic control
Electronic remote
control
Electronic remote
control
Remote control Yes / No Yes Yes
Air filter type(s) Mesh Mesh
Refrigerant type / filling C / g R410A / 1800
R410A / 2300
Refrigerant GWP 2088
2088
CO2 equivalent
3.759 4.803
Diameter refrigerant piping Fluid - Gas mm 1/4“ / 3/8” 1/4“ / 3/8” 1/4“ / 3/8” 1/4“ / 3/8”
Normal suction / discharge pressure (max) bar 8.5 / 30.5 (12 / 41) 8.5 / 30.5 (12 / 41) 11.5 / 19 (28.5 / 45) 11.5 / 19 (28.5 / 45)
Dimensions indoor unit (WxHxD) mm 811x292x205 811x292x205
Dimensions outdoor unit (WxHxD) mm 780x605x290
902x650x307
Net weight indoor unit kg 8.5 9.0
Net weight outdoor unit kg 40
50
Gross weight indoor unit kg 10.5 11
Gross weight outdoor unit kg 44
55
Sound level indoor unit**** dB(A) 40 40
Sound level outdoor unit**** dB(A) 55
58
Sound pressure level indoor unit (low)**** dB - -
Protection indoor unit IP IPX0 IPX0
Protection outdoor unit IP IPX4
IPX4
Allowable power fuse AC 250V / 3.15A AC 250V / 3.15A AC 250V / 3.15A AC 250V / 3.15A
* EN 14511/EN 14825
** Use indicative
*** Remove moisture at 27°C, 60% RL
**** EN 12108
4
55
4
54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tectro TSM8 DUO and is the answer not in the manual?

Tectro TSM8 DUO Specifications

General IconGeneral
BrandTectro
ModelTSM8 DUO
CategoryAir Conditioner
LanguageEnglish