MAINTENANCE INSTRUCTIONS
98-01580-EN-R0_A4LT-E-ChemSaver-MaintenanceInstructions-TB.docx
6
TROUBLESHOOTING
This is a list with the most common e-ChemSaver’s failures.
NOZZLE LEAKING
After setting off the spray, some nozzles are still leaking.
Issue/Problem Solution Example
Plunger’s gasket damaged
Change the kit plunger-gasket
(Reference AB115880-2-KIT).
Solid particles present in the
gasket
Remove any solid particle present.
Clean smoothly with pressurized air.
Sand Dust Blocking the Closure
Metal Chip Inserted In The Gasket
Stuck plunger in the cylinder
due to solid/liquid particles
Clean with water. Stucked Plunger Free Plunger