4.3 Warranty card
NTC brake
NTC short
E-stop
MID
RFID
CP
communication
flash
flash
flash
flash
flash
flash
Temp
Brake
Temp
Short
Gun
Fault
EStop
Fault
Meter
Fault
Card
Fault
0x0020
0x0040
0x0080
0x0400
0x0100
0x0200
9
8
7
11
6
10
Solution
The temperature sensor is in open circuit, charging stops and the relay is
cut off. Unit must be returned to factory for repair.
The temperature sensor has a short circuit, charging stops and the relay is
cut off. Unit must be returned to factory for repair.
The CP of the charging cable is short-circuited, stop charging and cut
power to the charger. Have cable inspected by a qualified electrician.
If for whatever reason the red emergency stop button is pressed the
charging will immediately stop. Press again to resume charging.
Can not communicate with the meter for more than 5 seconds, charging
stops and the relay is cut off, charging resumes once communication is
resumed.
Can not communicate with the RFID mode for more than 5seconds,
charging stops and the relay is cut off, charging resumes once
communication is resumed.
Condition
Display
code
LCD
display
Status
indicator light
Status
indicator light