Operating instructions
(Translation of the original operating instructions)
Filter device type
ECO-Cube
TEKA Absaug- und Entsorgungs-
technologie GmbH
Industriestraße 13 D-46342 Velen
Postfach 1137 D-46334 Velen
Tel.: +49 (0) 2863 9282-0
Fax: +49 (0) 2863 9282-72
E-Mail:
sales@teka.eu
www.teka.eu

Questions and Answers

  • C
    Candice MarshallAug 4, 2025
    How to troubleshoot a Teka ECO-Cube Fan system that does not start?
    • G
      garciabrittanyAug 5, 2025
      If the Teka Fan system doesn't start, first ensure the main switch (pos. 14) is in the ON position. Then, check the power supply plug to make sure it's correctly inserted. Finally, verify that there is power at the outlet and address any mains errors.
  • M
    Mr. Mario KennedyAug 10, 2025
    Why is the suction power too low on my Teka ECO-Cube Fan?
    • M
      Molly ColemanAug 10, 2025
      If the suction power of your Teka Fan is too low, and smoke is hardly extracted, several issues could be the cause. Check if the filter elements are saturated and connect compressed air. Inspect the capturing elements for any damage and replace them if necessary. Ensure the clean air outlet and suction line are not contracted; fix any errors found. Also, verify that the throttle valve in the detection element extraction hood is open.
  • J
    John RobinsonAug 16, 2025
    What to do if there is dust at the dust collector of my Teka ECO-Cube?
    • D
      Dwayne WolfeAug 17, 2025
      If you notice dust at the dust collector of your Teka Fan, it could be due to several reasons. First, the dust collection container might be too full, so empty it. Ensure that the toggle closures are securely closed. Check the seal of the dust collection container for any damage and renew it if necessary. Also, the compressed air for dedusting might be set too high; reduce it accordingly.
  • T
    Tyler StoneAug 22, 2025
    Why is my Teka Fan so noisy?
    • M
      Melissa MatthewsAug 22, 2025
      If your Teka Fan unit is very noisy, several factors could be responsible. Ensure the curved silencer (pos. 10) is properly mounted. Verify that the intake and exhaust air pipes are correctly mounted. Check the filter unit for any untight areas.
  • H
    hubbardpaulaAug 29, 2025
    What causes dust at the service door of a Teka Fan?
    • G
      Gail FriedmanAug 29, 2025
      If you find dust at the service door of your Teka Fan, make sure all door levers are closed. Inspect the seal between the service door and filter housing for damage and replace it if needed. Reduce the compressed air if it's set too high. Also, check the hinge; it may need reorientation or replacement.

Summary

TEKA ECO-Cube Operating Instructions

System Components and Parts List

Intended Use of the Filter System

Safety Instructions and Misuse Warnings

Fire Hazard Precautions

Addresses fire risks and outlines necessary immediate actions and preventative measures.

Storage, Transport, and Installation

Step-by-Step Installation Guide

Detailed instructions for assembling and installing the ECO-Cube filter system on-site.

System Commissioning Procedures

Electrical Connection Safety

Instructions for safely connecting the filter system to the electrical power supply.

Compressed Air Supply Setup

Procedure for connecting the compressed air for the automatic cleaning function.

Routine Maintenance and Servicing

Filter Cartridge Replacement

Detailed steps for replacing used filter cartridges with new ones.

Operating the Filter System

Dismantling and Disposal Procedures

Troubleshooting System Faults

Technical Specifications

Maintenance Intervals

Electrical Lines and Earthing Test

Testing electrical lines and earthing connections for safety and proper function.