Specifications
Input Voltage (230 VAC nominal range)
Continuous RMS Power Output at 115VAC or 230VAC in;
convection cooled.
225W RMS 0-40°C ambient 350W RMS 0-40°C ambient
Continuous RMS Power Output at 115VAC or 230VAC in; fan
cooled.
N/A 500W RMS 0-40°C ambient
Peak Power Capability at 115VAC or 230VAC in
Regenerated Energy / Power Absorption 12.7 joules / 13.3 watts RMS at 40°C 19.1 joules / 13.3 watts RMS at 40°C
Capacitive Energy Storage
Allowable (user added) output capacitance
Min. equivalent startup load
Weight 2.11 lbs. 2.25 lbs.
Dimensions 181mm x 132mm x 57.3mm 183mm x 132mm x 57.3mm
Finger Safe No. User must be protected from shock hazard. Yes
Enclosure None Perforated, epoxy coated steel
Certifications/Compliance
Output Short-Circuit Protection
Output bus dump load control
Hiccup mode with auto-recovery
Halts power delivery until power removal/reapplication
During Regeneration: Initiated at 92VDC, off at 88VDC;
At power-off: Initiated within 200mS of AC power removal, off when output is below ~12VDC
Meets EN55011/22 Class A requirements
Halts power delivery until voltage returns to specified output voltage
Hiccup mode with auto-recovery
10% - 90% (non-condensing)
50 dB under light or no load, intermittent noise
< 500mV P-P, zero to full load
16 ohms @ AC input 105/210V min.
900W for 3 sec. (single pulse load at 40°C)
Input Voltage (115 VAC nominal range)
108 -125VAC (start under load at ambient temps 0-15°C)
95-125VAC (load independent at ambient temps 15-40°C)
Input Voltage (230 VAC nominal range)
Continuous RMS Power Output at 115VAC or 230VAC in;
convection cooled.
225W RMS 0-40°C ambient 350W RMS 0-40°C ambient
Continuous RMS Power Output at 115VAC or 230VAC in; fan
cooled.
N/A 500W RMS 0-40°C ambient
Peak Power Capability at 115VAC or 230VAC in
Regenerated Energy / Power Absorption 12.7 joules / 13.3 watts RMS at 40°C 19.1 joules / 20 watts RMS at 40°C
Capacitive Energy Storage
Allowable (user added) output capacitance
Min. equivalent startup load
Weight 2.11 lbs. 2.25 lbs.
Dimensions 181mm x 132mm x 57.3mm 183mm x 132mm x 57.3mm
Finger Safe No. User must be protected from shock hazard. Yes
Enclosure None Perforated, epoxy coated aluminum
Acoustic Noise @ 1 distance = meter
Certifications/Compliance
Output Short-Circuit Protection
Output bus dump load control
Hiccup mode with auto-recovery
Halts power delivery until power removal/reapplication
During Regeneration: Initiated at 92VDC, off at 88VDC;
At power-off: Initiated within 200mS of AC power removal, off when output is below ~12VDC.
Meets EN55011/22 Class A requirements
Halts power delivery until voltage returns to specified output voltage
Hiccup mode with auto-recovery
10% - 90% (non-condensing)
<50 dBA (variable, dependent on load and AC line)
< 500mV P-P, zero to full load
16 ohms @ AC input 105/210V min.
900W for 3 sec. (single pulse load at 40°C)
Input Voltage (115 VAC nominal range)
108 -125VAC (start under load at ambient temps 0-15°C)
95-125VAC (load independent at ambient temps 15-40°C)
6