1) Set the front panel controls as follows:
RF CENTER FREQUENCY
10 MHz
DISPERSION RANGE
MHz/DIV
DISPERSION
5 MHz/div
IF ATTENUATOR
20 dB
VERTICAL DISPLAY
LIN
TIME/DIV
5 ms
Band Selector
A
2) Apply the output signal from a signal generator
within the frequency range of band A, to the band A
RF INPUT connector.
3) Set the generator frequency and the RF center fre-
quency to the frequencies that are listed in Table 6-7.
Adjust the signal generator output attenuator and the
Type 491 GAIN control for a signal amplitude of 6 divi-
sions.
4) Check band A display flatness by tuning the signal
from the display screen left edge to the right edge with
the RF CENTER FREQUENCY control. (Frequency range +
and -25 MHz of the RF center frequency.) Signal ampli-
tude should not change more than ±1.5 dB from its
average amplitude or 3 dB total.
TABLE 6-7
RF Center
Applied Signal
Frequency Generator Freq.
10 MHz-60 MHz
35 MHz
50 MHz-100 MHz
75 MHz
100 MHz-150 MHz
125 MHz
150 MHz-200 MHz
175 MHz
200 MHz-250 MHz
225 MHz
250 MHz-275 MHz
275 MHz
5) Remove the signal to band A, RF INPUT and apply
a signal within the frequency range of band B to RF INPUT
B. Set
the band selector to B and set the DISPERSION to
10 MHz/div.
TABLE 6-8
6) Check display flatness as per Table 6-8. 3 dB maxi-
mum amplitude variation over 100 MHz
window (±50 MHz
from
RF center frequency). Maximum signal amplitude
with the MIXER PEAKING control before measuring flat-
ness.
7) Remove the signal from band B INPUT and apply
the output from signal generators, that cover scales 4
through 6 frequency range, to band C Coaxial Mixer.
8) Check response flatness through the frequency range
of the Coaxial Mixer. Maximum amplitude variation over
100 MHz dispersion window must not exceed 3 dB. Adjust
MIXER PEAKING for maximum signal amplitude before
measuring flatness.
9) Replace the Coaxial Mixer with the Waveguide Mixer
Adapter.
10) Apply the output from o signal generator, within
the frequency range of scale 8 and 9 through one of the
Waveguide Mixers and the 2 foot cable (with the BNC
connectors) to band C Waveguide Adapter.
11) Check response flatness for the frequency range
above 12.4 GHz. Maximum amplitude variation over 100
MHz dispersion window must not exceed 6 dB. Adjust
Mixer PEAKING for maximum signal amplitude before
measuring flatness.
6-38