Home
Tektronix
Measuring Instruments
47E5A
Tektronix 47E5A
83 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
I
I
I
I
I
I
I
I
I
I
.
Tektronix,
Inc
.
P.O.
Box
500
Beaverton,
Oregon
97077
070·2163
·
00
TEKTRONIX®
47E5A
DSCILLDSCDPE
AND
DM44
DIGITAL
MULTIMETEA
PEA
INSTRUCTION
MANUAL
Serial
Number
___
Fi
r
st
Printing
AUG.
1976
2
Table of Contents
Main Page
Table of Contents
3
List of Illustrations
6
Controls,Connectors,And Indicators
6
List of Tables
7
Before Operating
9
Introduction
9
Safety Information
9
Operating Voltage
10
Line Voltage Selection
10
Regulating Range Selection
10
Options
11
Controls,Connectors,And Indicators
12
Vertical
12
Display
15
Dm44
15
Trigger
16
Horizontal, Calibrator, and Power
20
Rear Panel
22
Left Side Panel
22
Right Side Panel
22
Basic Oscilloscope Displays
24
Normal Sweep Display
24
Magnified Sweep Display
25
Delayed Sweep Display
25
Mixed Sweep Display
26
X-Y Display
26
Single Sweep Display
27
Dm44 Displays and Measurements
28
Resistance
28
Volts
30
Temperature
32
Accuracy Check
32
Time and 1/Time
35
Applications and Measurements
36
Preliminary
36
Signal Ground
36
Input Coupling Capacitor Precharging
36
Operator's Adjustments and Checks
37
Trace Rotation
37
Probe Compensation
37
Vertical Gain Check
38
Basic 475A Timing Check
38
DM44 Timing Check
38
External Horizontal Gain Check
39
Peak-To-Peak Voltage Measurements-Ac
39
Instantaneous Voltage Measurements-DC
40
Algebraic Addition
42
Common Mode Rejection
43
Amplitude Comparison Measurements
44
Time-Duration Measurements
45
Frequency Measurements
46
Risetime Measurements
47
Time Difference between Two Pulses from Different Sources
48
Time Comparison Measurements
49
Phase Difference Measurements
50
High Resolution Phase Difference Measurements
51
Pulse Jitter Measurements
52
Delayed or Mixed Sweep Magnification
53
Magnified Sweep Starts after Delay
53
Triggered Delay Sweep Magnification
54
Basic 475A Delayed or Mixed Sweep Time Measurements
56
Time Difference between Repetitive Pulses (Basic 475A)
56
Time Duration Measurements
57
(Basic 475A)
57
Frequency Measurements (Basic 475A)
58
Time Difference between Two Pulses from Different Sources (Basic 475A)
59
Risetime (Basic 475A)
60
Measurements
61
MIX (Basic 475A)
61
Time Difference between Repetitive Pulses (Dm44)
64
Time Duration Measurements (Dm44)
65
Frequency Measurements (Dm44)
66
Time Difference between Two Pulses
66
Risetime (Dm44)
68
MIX (Dm44)
69
Vertical
70
Operator's Specifications
70
Triggering
71
Differential Time Measurement
71
(Basic 475A)
71
Differential Time Measurement
72
(Dm44)
72
Horizontal
72
Calibrator
72
Z Axis Input
73
Outputs
73
Ac Power Source
73
Environmental
73
Dm44 Digital Multimeter
74
Resistance
74
Time
74
Temperature
74
DC Voltage
74
Accessories
76
Standard Accessories
76
Optional Accessories
76
Options
77
Need help?
Do you have a question about the Tektronix 47E5A and is the answer not in the manual?
Ask a question
Tektronix 47E5A Specifications
General
Bandwidth
500 MHz
Rise Time
700 ps
Input Impedance
50 Ω
Maximum Input Voltage
5 Vrms
Length
1.5 m
Connector Type
BNC
Input Coupling
AC, DC
Attenuation
10X
Related product manuals
Tektronix 475A
80 pages
Tektronix 491
226 pages
Tektronix 492
303 pages
Tektronix Keithley 4200A-SCS
324 pages
Tektronix 1910
43 pages
Tektronix A622
28 pages
Tektronix P6015
26 pages
Tektronix DMM830
42 pages
Tektronix AA 501
161 pages
Tektronix Series
104 pages
Tektronix KEITHLEY 2450-EC
93 pages
Keithley SourceMeter 2470
84 pages