Loading...
Do
not
exceed
mixer
input
limits
.
Refer
to
the
external
mixer
operating
instructions
at
the
end
of
the
General
Operating
Information
part
of
this
section
.
34
CAUTION
2-12
PEAKING
.
This
control
varies
mixer
bias
for
external
mixers
in
the
EXT
MIXER
mode
.
If
the
492
has
a
preselector
(
Option
1
)
,
the
control
also
adjusts
the
preselector
filter
tracking
for
the
1.7
to
21
GHz
frequency
range
(
Bands
2-5
)
.
In
both
cases
it
is
adjusted
for
maximum
signal
amplitude
.
Refer
to
External
Mixer
Operation
for
more
detailed
instructions
.
Rear
Panel
(
Fig
.
2-2
)
1
EXT
IN
HORIZ
/
TRIG
.
Dc
coupled
input
for
horizontal
drive
voltages
and
ac
coupled
for
trigger
signal
.
A
to
+10
volt
ramp
produces
full
sweep
.
0.5
to
50
volt
peak
signals
are
required
for
trigger
(
0.1
us
minimum
pulse
width
)
,
15
Hz
to
1
MHz
.
Selection
as
to
HORIZ
or
TRIG
mode
depends
on
front
panel
TRIGGERING
and
TIME
/
DIV
selections
.
2
3
5
4
VERT
(
output
)
.
Source
of
a
signal
that
is
0.5
V
for
each
division
of
display
.
6
PROBE
POWER
.
Provides
operating
voltage
(
±
15
V
and
+5
V
)
for
active
probes
,
such
as
TEKTRONIX
P6056
or
P6021
.
Refer
to
probe
instruction
manuals
for
operating
procedures
.
7
HORIZ
(
output
)
.
Source
of
a
signal
that
is
0.5
V
for
each
division
of
display
.
PEN
LIFT
.
TTL
compatible
,
nominal
+5
V
provid
ed
to
lift
the
pen
of
a
chart
recorder
.
10
MHz
IF
(
+20
dBm
max
)
.
Access
to
the
10
MHz
IF
signal
.
Output
level
is
about
-10
dBm
with
a
full
screen
signal
at
-30
dBm
reference
level
,
maximum
output
is
+20
dBm
.
J104
ACCESSORY
.
Possible
future
applications
for
the
492
may
use
this
connector
.
492
Operator's
Handbook

Other manuals for Tektronix 492

Related product manuals