OPTION 21
(WM 490-2)
Includes: High Performance Waveguide Mixers; 18 to 40 GHz mixers and cable as listed.
Specification492/492P Service Vol. I (SN B030000 & up)
Frequency Response
Frequency Range Nomenclature
Sensitivity: Equivalent Input
Noise @ 1 kHz Bandwidth
(Maximum)
Mean Average
Referenced
to
100 MHz
18.0—26.5 GHz
WM490K
-100 dBm ±3.0 dB
± 6 dB
26.540 GHz
WM490A
95 dBm
±3.0 dB
± 6 dB
Cable: SMA-to-SMA connector, 012-0649-00
OPTION 22
(WM 490-3)
Includes: High Performance Waveguide Mixers: 18 to 60 GHz mixers and cable as listed.
Frequency Response
Frequency Range Nomenclature
Sensitivity: Equivalent Input
Noise @ 1 kHz Bandwidth
(Maximum)
Mean Average
Referenced
to
100 MHz
18.0—26.5 GHz
WM490K
100 dBm
±3.0 dB ± 6 dB
26.540 GHz
WM490A
-95 dBm
±3.0 dB ± 6 dB
40—60 GHz
WM490U
95 dBm
±3.0 dB ± 6 dB
Cable: SMA-to-SMA male connector, 012-0649-00
NOTE
These characteristics assume that the waveguide mixer is connected to a cw signal source and that the PEAKING
control is adjusted for maximum signal amplitude. The signal must be stable (not frequency modulated more than
the resolution bandwidth); otherwise, frequency response specifications cannot be met.
OPTION 30
Rackmount version of 492/492P Spectrum Analyzer. (See Rackmount/Benchtop Versions, Section 6 .)
OPTION 31
Rackmount version of 492/492P with cables from front panel to back of the cabinet. (See Section 6 .)
OPTION 32
Benchtop version of 492/492P Spectrum Analyzer. (See Section 6 .)
REV AUG 1981 1-19