Commands Listed in Alphabetical Order
Group
Waveform Trans
fer
Syntax
DATa:ENCdg
{ASCIi|FAStest|RIBinary|R PBinary|SRIbinary|SRPbinary}
DATa:ENCdg?
Related Commands
WFMOutpre:ENCdg, WFMOutpre:BN_Fmt, WFMInpre:FILTERFreq
Arguments
ASCIi species the ASCII representation for waveform data points. If ASCII is
the value, then :BN_Fmt and :B
YT_Or are ignored.
FAStest species that the data be sent in the fastest possible manner consistent
with maintaining accuracy and is interpreted with respect to the waveform
specied by DATa:SOUrce.
RIBinary species signed integer data point representation with the most
signicant byte transferred rst.
When :BYT_Nr is 1, the rang
e is from –128 through 127. When :BYT_Nr is 2,
the range is from –32,768 through 32,767. Center screen is 0 (zero). The upper
limit is the top of the screen and the lower limit is the bottom of the screen. This
is the default argument.
RPBinary species the p
ositive integer data-point representation, with the most
signicant byte transferred rst.
When :BYT_Nr is 1, the range from 0 through 255. When :BYT_Nr is 2, the
range is from 0 to 65,535. The center of the s creen is 127. The upper limit is the
topofthescreenandt
he lower limit is the bottom of the screen.
SRIbinary is the same as RIBinary except that the b yte order is swapped,
meaning that the least signicant byte is transferred rst. This format is useful
when transferring data to IBM compatible PCs.
SRPbinary is the same as RPBinary except that the b yte order is swapped,
meaning that the least signicant byte is transferred rst. This format is useful
when transferring data to PCs.
Table 2-36: DATa and WFMOutpre Parameter Settings
WFMOutpre Settings
DATa:ENCdg
Setting :ENCdg :BN_Fmt :BYT_Or :BYT_NR
ASCii ASC N/A N/A
1,2
FAStest
BIN RI
MSB
1,2
RIBinary BIN RI
MSB
1,2
RPBinary BIN RP
MSB
1,2
SRIbinary
BIN RI
LSB
1,2
SRPbinary
BIN RP
LSB
1,2
2-128 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals