Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:I2C:ADDRess:VALue <QString>
TRIGger:A:BUS:B<x>:I2C:AD DRess:VALue?
Arguments
<QString> is up to 7 or 10-bits depending on the address mode that species the
address.Theonlyallowedcharactersinthe
QString are0,1,andX.
Examples
TRIGGER:A:BUS:B1:I2C:ADDR ESS:VALUE 1011 sets the I
2
C address value
to XXX1011.
TRIGger:A:BUS:B<x>:I2C:CONDition
Sets or returns the trigger condition for an I
2
C trigger. Applies to bus <x>, where
x is the bus number.
Conditions
This command requires a DPO2EMBD application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:I2C:CO NDition
{STARt|STOP
|REPEATstart|ACKMISS|ADDRes s|DATA|ADDRANDDATA}
TRIGger:A:BUS:B<x>:I2C:CO NDition?
Argument
s
STARt speci es a search based on start condition.
STOP species a search based on stop condition.
REPEATstart species a search based on repeat of start condition.
ACKMIS
S
species a search based on missing acknowledgement condition.
ADDRess species a search based on address.
DATA species a search based on data.
ADDRANDDATA species a search based on address and data.
Examples
TRIGGER:A:BUS:B1:I2C:COND ITION START species start as the I
2
Ctrigger
condition.
2-302 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals