Commands Listed in Alphabetical Order
CARea (cycle ar
ea) measures the voltage over time. In other words, it measures, in
volt-seconds, the area over the rst cycle in the waveform or the rst cycle in the
gated region. The area measured above t he common reference point is positive,
while the area below the common reference point is negative. This measurement
is available only on DPO models.
CMEan (cycle mean) measures the a rithmetic mea n over the rst cycle in the
waveform or the rst cycle in the gated region. This measurement is available
onlyonDPOmodels.
CRMs (cycle rms) measures the true Root Mean Square voltage over the rst
cycle in the waveform or the rst cycle in the gated region. This measurement is
availabl
e only on DPO models.
DELay measures the time between the middle reference (default = 50%) amplitude
point of
the source waveform and the destination waveform. This measurement is
available only on DPO models.
FALL me
asures the time taken for the falling edge of the rst pulse in the
waveform or gated region to fall from a high reference value (default is 90%) to
a low reference value (default is 10%). This measurement is available only on
DPO models.
FREQuency measures the rst cycle in the waveform or gated region. Frequency
is the reciprocal of the period and is measured in hertz (Hz), where 1 Hz = 1
cycle per second.
HIGH measures the High reference (100% level, sometimes called Topline) of a
waveform. This measurement is available only on DPO models.
LOW measures the Low reference (0% level, sometimes called Baseline) of a
waveform. This measurement is available only on DPO models.
MAXimum nds the maximum amplitude. This value is the most positive peak
voltage found. It is measured over the entire waveform or gated region. This
measurement is available only on DPO models.
MEAN amplitude measurement nds the arithmetic mean over the entire waveform
or gated region. This measurement is available only on DPO models.
MINImum nds the minimum amplitude. This value is typically the most negative
peak voltage. It is measured over the entire waveform or gated region. This
measurement is available only on DPO models.
NDUty (negative duty cycle) is the ratio of the negative pulse width to the signal
period, express ed as a percentage. The duty cycle is measured on the rst cycle in
the waveform or gated region.
Negative Duty Cycle = ((Negative Width) / Period) × 100%
NEDGECount is the count of negative edges.
2-204 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix DPO2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2024 and is the answer not in the manual?

Tektronix DPO2024 Specifications

General IconGeneral
BrandTektronix
ModelDPO2024
CategoryTest Equipment
LanguageEnglish

Related product manuals