Commands Listed in Alphabetical Order
2 horizontal li
nes drawn on the graticule. The indicators show where the
measurement specied by MEASUrement:INDICators:STATE is being
performed.
MEASUrement
:INDICators:NUMVERT? (Query Only)
Returns the number of vertical measurement indicators currently being displayed.
Group
Measurement
Syntax
MEASUrement:INDICators:NU MVERT?
Examples
MEASUREMENT:INDICATORS:NU MVERT? might return
MEASUREMENT:INDICATORS:NU MVERT 2 indicating that there are currently 2
vertic
al lines drawn on the graticule. The indicators show where the measurement
specied by MEASUrement:INDICators:STATE is being performed.
MEASUrement:INDICators:STATE
Sets or returns the state of visible measurement indicators.
Group
Measurement
Syntax
MEASUrement:INDICators:ST ATE {OFF|MEAS<x>}
MEASUrement:INDICators:ST ATE?
Arguments
OFF turns the visible measurement indicators off.
MEAS<x> displays the visible measurement indicators for measurement <x>,
where<x>canbe1,2,3,or4.
NOTE. Theremustbeanactivemeasurementbefore you can activate an indicator
for a specied measurement.
Examples
MEASUREMENT:INDICATORS:ST ATE MEAS2 turns on the display of visible
measurement indicators for measurement 2.
MEASUREMENT:INDICATORS:ST ATE? might return
MEASUREMENT:INDICATORS:ST ATE OFF indicating that no measurement
indicators are active.
2-196 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual