Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:RUNT:WHEn {LESSthan|MOREt han|EQual|UNEQu al|OCCURS}
TRIGger:A:RUNT:WHEn?
Related Commands
TRIGger:A:RUNT:WIDth
Arguments
OCCURS argument specifies a t rigger event if a runt of any detectable width occurs.
LESSthan argument sets the oscilloscope to trigger if the a runt pulse is detected
with width less than the time set by the TRIGger:A:RUNT:WIDth command.
MOREthan argument sets the oscilloscope to trigger if the a runt pulse is detected
with width more than the time set by the TRIGger:A:RUNT:WIDth command.
EQUal argument sets the oscilloscope to trigger if a runt pulse is detected with
width equal to the time period specified in TRIGger:A:RUNT:WIDth within
a ±5% tolerance.
UNEQual argument sets the oscilloscope to trigger if a runt pulse is detected with
width greater than or less than (but not equal to) the time period specified in
TRIGger:A:RUNT:WIDth within a ±5% tolerance.
Examples
TRIGGER:A:RUNT:WHEN THAN sets the runt trigger to occur when the
oscilloscope detects a runt in a pulse wider than the specified width.
TRIGGER:A:RUNT:WHEN? might return :TRIGGER:A:PULSE:RUNT:WHEN
OCCURS
indicating that a runt trigger will occur if the oscilloscope detects a runt
of any detectable width.
TRIGger:A:RUNT:WIDth
Sets or returns the width for a runt trigger.
Group
Trigger
Syntax
TRIGger:A:RUNT:WIDth <NR3>
TRIGger:A:RUNT:WIDth?
Related Commands
TRIGger:A:RUNT:WHEn
Arguments
<NR3> specifi es the minimum width, in seconds.
2-332 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual