Command Descriptions
2−132
TDS200/1000/2000 Series Oscilloscope Programmer Manual
SAVe:SETUp <NR1>
<NR1> is an integer value in the range from 1 to 5 (TDS200 series) or
10 (TDS1000 and TDS2000 series) and specifies a memory location.
Any settings that have been stored previously at this location are
overwritten.
SAVe:SETUp 5
saves the current front-panel setup to memory location 5.
RECAll:SETUp, *RCL, *SAV
SAVe:WAVEform (No Query Form)
Stores a waveform in one of the nonvolatile reference memory
locations. This command is equivalent to selecting the Save
Waveform option in the Save/Recall Waveform menu.
Save and Recall
SAVe:WAVEform <wfm>, REF<x>
<wfm> is CH<y> (one of the allowable channels) or MATH. This is the
waveform that will be saved.
REF<x> is one of the allowable reference waveform storage
locations.
SAVe:WAVEform MATH, REFB
saves the math waveform in stored waveform memory location
REFB
SELect:<wfm> causes a saved reference waveform to be displayed.
Syntax
Arguments
Examples
Related Commands
Group
Syntax
Arguments

Table of Contents

Other manuals for Tektronix TDS1012

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS1012 and is the answer not in the manual?

Tektronix TDS1012 Specifications

General IconGeneral
BrandTektronix
ModelTDS1012
CategoryTest Equipment
LanguageEnglish

Related product manuals