Command Descriptions
2−138
TDS200/1000/2000 Series Oscilloscope Programmer Manual
TRIGger FORCe
forces a trigger event to occur.
TRIGger?
might return
:TRIGGER:MAIN:MODE AUTO;TYPE EDGE;LEVEL 0.0E0;HOLD−
OFF:VALUE 5.0E–7;:TRIGGER:MAIN:EDGE:SOURCE CH1;COUPLING
DC;SLOPE RISE;:TRIGGER:MAIN:VIDEO:SOURCE CH1;SYNC
FIELD;POLARITY NORMAL
TRIGger:MAIn
Sets the oscilloscope trigger level to 50% of the minimum and
maximum values of the signal. Returns the current main trigger
parameters when used as a query.
Trigger
TRIGger:MAIn SETLevel
TRIGger:MAIn?
SETLevel sets the main trigger level to half way between the MIN
and MAX amplitudes of the trigger source input. This is equivalent
to pressing the front-panel SET LEVEL TO 50% button.
If the oscilloscope acquisition state is STOP and you send
TRIGger:MAIn SETLevel, the oscilloscope ignores the command
and generates event 221 (Settings conflict).
TRIGger:MAIn SETLEVel
sets the main trigger level mid way between MAX and MIN.
Examples
Group
Syntax
Arguments
Examples