IT - SENSORE PIOGGIA VIA RADIO 24VDC RISCALDATO PER CENTRALI DI COMANDO COMPATIBILI
EN  24VDC HEATED RADIO RAIN SENSOR TO BE USED WITH COMPATIBLE CONTROL UNITS
FR - CAPTEUR RADIO PLUIE 24VDC CHAUFFÉ POUR CENTRALES DE COMMANDE COMPATIBLES.
DE  BEHEIZTER 24 VDC FUNKREGENSENSOR FÜR KOMPATIBLE STEUERUNGEN
ES - SENSOR DE LLUVIA RADIO 24VDC CALENTADO PARA CENTRALES DE MANDO COMPATIBLES
RAIN103
IT - Codice prodotto EN - Product code
FR - Code du produit DE - Artikelnummer
ES - Codigo del producto
IT - Funzionamento: il sensore rileva la presenza di gocce d’acqua sulla supercie sensibile. E’ possibile abilitare la funzione di riscaldamento in
maniera permanente o solo in caso di allarme pioggia. Il rilevamento dell’allarme pioggia viene fatto con un ritardo di 3s. La sensibilità di misurazione
è congurabile. EN - Functioning - The sensor detects the presence of water drops over the sensitive pad. It’s possible to enable the heating function
in permanently way or only in case of rain alarm. Rain alarm detection is done with a 3s delay. The measurement sensitivity can be congured.
FR - Fonctionnement - Le capteur détecte la présence de goutes de pluie via sa surface sensitive. Il est possible d’activer la fonction de chauffage
de façon permanente ou seulement en cas d’alarme pluie. La détection de l’alarme pluie se fait avec un retard de 3s. La sensibilité de mesurage
peut être congurée. DE - Funktionsweise - Der Sensor ermittelt die Regentropfen auf der sensiblen Oberäche. Die Beheizungsfunktion kann auf
permanente Weise oder nur im Fall von Regenallarm aktiviert werden. Die Regenerkennung hat eine Verzögerung von 3 Sek. Die Sensibilität der
Messung ist kongurierbar. ES - Funcionamiento: el sensor detecta la presencia de gotas de agua por encima de la supercie sensible. Es posible
activar la función de calefacción de forma permanente o solo en caso de alarma de lluvia. La detección de la alarma de lluvia se realiza con un retraso
de 3 segundos. La sensibilidad del sensor es congurable.
IT - INSTALLAZIONE EN  INSTALLATION FR - INSTALLATION DE  INSTALLATION ES - INSTALACIÓN
IT - Funzione riscaldamento (se temperatura < 4°C)
EN - Heating function (if temperature < 4°C)
FR - Chauffage intégré (si la température < 4°C)
DE - Funktion Beheizung (wenn Temperatur < 4°C)
ES - Función de calefacción (si la temperatura < 4°C)
120 mm
75 mm
2900 mm
130 mm
37 mm
50 mm
120 mm
75 mm
2900 mm
130 mm
37 mm
50 mm
IT - Magnete di programmazione
EN - Programming magnet
FR - Aimant de programmation
DE - Programmiermagnet
ES - Magneto de programación
120 mm
75 mm
130 mm
37 mm
50 mm
2900 mm
(Max. 10m)
OFF
IT - Funzione riscaldamento
EN - Heating function
FR - Chauffage intégré
DE - Funktion Beheizung
ES - Función de calefacción
ON
IT - Sensibilità media
EN - Sensitivity medium
FR - Sensibilité moyenne
DE - Empndlichkeit mittel
ES - Sensibilidad media
M
Valori di fabbrica - Default values - Valeurs
prédénie - Standardwerte - Valores predenidos
TELECO AUTOMATION SRL
Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com
DOC.: T797.01
RAIN103
DATE: 18/02/19
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
GND (-)
nero, black, noir, schwarz, negro
+24V
rosso, red, rouge, rot, rojo
Question and Answer IconNeed help?

Do you have a question about the Teleco RAIN103 and is the answer not in the manual?

Summary

RAIN103 Sensor Introduction

Product Functionality and Operation

Describes how the sensor detects water drops and its heating function capabilities.

Physical Components and Installation

Details the sensor's parts, power connections, and installation requirements.

Default Settings Overview

Outlines the factory default values for sensitivity and heating modes.

Radio Channel Configuration Procedures

Setting the Rain Channel

Step-by-step guide to configure the rain channel using a programming magnet.

Configuring CH7 Transmission

Procedure for setting the CH7 transmission channel for compatible products.

Configuring CH5 Transmission

Procedure for setting the CH5 transmission channel for non-compatible products.

Sensor Feedback and Sensitivity Adjustment

Interpreting LED Status Indicators

Explains the meaning of different LED patterns for status and errors.

Adjusting Sensor Sensitivity Levels

Details the process of setting the sensor's sensitivity using a programming magnet.

Heating Function Management

Activating and Deactivating Heating

Instructions for enabling and disabling the permanent heating function.

Managing Conditional Heating

Guide for activating/deactivating heating based on temperature thresholds.

Advanced Sensor Operations

Sensor Calibration Process

Steps to calibrate the sensor for abnormal functioning or optimal performance.

Device Pairing and Memorization

Procedure for memorizing the sensor with a compatible receiver.

Rain Alarm Mode Logic

Explains when the rain alarm condition is activated in the control unit.

Safety, Compliance, and Disposal

Installation and Maintenance Guidelines

Covers qualified personnel, cleaning, and general installation practices.

Product Disposal and Declarations

Details how to dispose of the product and mentions compliance declarations.

Technical Specifications

Detailed Product Specifications

Lists key technical data including power, temperature, frequency, and protection rating.

Summary

RAIN103 Sensor Introduction

Product Functionality and Operation

Describes how the sensor detects water drops and its heating function capabilities.

Physical Components and Installation

Details the sensor's parts, power connections, and installation requirements.

Default Settings Overview

Outlines the factory default values for sensitivity and heating modes.

Radio Channel Configuration Procedures

Setting the Rain Channel

Step-by-step guide to configure the rain channel using a programming magnet.

Configuring CH7 Transmission

Procedure for setting the CH7 transmission channel for compatible products.

Configuring CH5 Transmission

Procedure for setting the CH5 transmission channel for non-compatible products.

Sensor Feedback and Sensitivity Adjustment

Interpreting LED Status Indicators

Explains the meaning of different LED patterns for status and errors.

Adjusting Sensor Sensitivity Levels

Details the process of setting the sensor's sensitivity using a programming magnet.

Heating Function Management

Activating and Deactivating Heating

Instructions for enabling and disabling the permanent heating function.

Managing Conditional Heating

Guide for activating/deactivating heating based on temperature thresholds.

Advanced Sensor Operations

Sensor Calibration Process

Steps to calibrate the sensor for abnormal functioning or optimal performance.

Device Pairing and Memorization

Procedure for memorizing the sensor with a compatible receiver.

Rain Alarm Mode Logic

Explains when the rain alarm condition is activated in the control unit.

Safety, Compliance, and Disposal

Installation and Maintenance Guidelines

Covers qualified personnel, cleaning, and general installation practices.

Product Disposal and Declarations

Details how to dispose of the product and mentions compliance declarations.

Technical Specifications

Detailed Product Specifications

Lists key technical data including power, temperature, frequency, and protection rating.

Teleco RAIN103 Specifications

General IconGeneral
BrandTeleco
ModelRAIN103
CategoryAccessories
LanguageEnglish