Do you have a question about the Teledyne T100 and is the answer not in the manual?
Technology | UV Absorption |
---|---|
Lower Detectable Limit | 0.5 ppb |
Resolution | 0.1 ppb |
Accuracy | ±1% of reading |
Linearity | ±1% of full scale |
Power Requirements | 100-240 VAC, 50/60 Hz |
Power Supply | 100-240 VAC, 50/60 Hz |
Measurement Range | 0-500 ppm |
Response Time | 60 seconds |
Span Drift | ≤1% of full scale/24 hours |
Operating Temperature | 5-40°C (41-104°F) |
Outputs | RS232 |
Dimensions | 19" x 5.25" x 16" (483 x 133 x 406 mm) |
Analyzer should only be used for purpose and manner described in manual; unpredictable behavior may ensue.
Introduces the instrument and presents procedures for unpacking, connections, and initial calibration.
Provides instructions for safely unpacking the T100 Analyzer and checking for shipping damage.
Instructions for making basic electrical connections and connecting optional I/O.
Provides pneumatic connection information, gas requirements, and layout illustrations.
Guides the user through startup, warning messages, and functional checks.
Describes initial calibration procedures for basic analyzers and optional sensors.
Explains how to switch the analyzer into calibration mode and use calibration functions.
Covers configuration of hardware/software features, diagnostic procedures, and data access.
Explains how to access diagnostic tools for troubleshooting and configuration.
Provides information on using external digital and serial I/O, and Hessen protocol for remote operation.
Details configuration of Ethernet, USB, and serial communication ports.
Explains the T100's internal DAS for storing concentration, calibration, and diagnostic data.
Describes calibration procedures for the T100, including preparations and manual/automatic methods.
Describes the basic method for manually calibrating the T100 SO2 analyzer.
Describes the AutoCal system for unattended, periodic operation of zero/span valve options.
Covers basic maintenance procedures to ensure accurate and reliable analyzer operation.
Details essential procedures for maintaining the T100 analyzer's performance and longevity.
Provides methods for identifying and solving performance problems with the analyzer.
Outlines a systematic approach to troubleshooting, including warning messages and test functions.
Provides information regarding possible causes of various calibration problems.
Details procedures for major component repair or replacement, including ESD precautions.
Provides essential anti-ESD procedures for working on the analyzer.