24 CA824 Alarm System User Manual
According to the attributes, the users can be classified as:
Basic user with permission to Full arm and disarm the system;
Standard user with permission to Full arm and disarm the system and to
bypass zones;
Special user with permissions of the standard user as well as the permission
to Force, Stay and Instant arm the system;
Manager with permission to fully operate the system. There is no limit for the
number user that can be managers.
User Limitations
Managers obey the following rules:
A manager can not assign a user more attributes than the manager has been
assigned;
A manager can not grant a user more rights than the manager has been
granted;
A manager can not change his own rights and attributes;
A manager can not change the rights or the attributes of an user that has more
rights than the manager.
All users, including the managers obey the following rules:
A user code is accepted only by keyboards/devices that are allowed to
operate at least one area that the user is also allowed to;
Even memory review for certain areas can be performed by users that are
assigned the Log View attribute and have the right to operate the respective
areas.