Do you have a question about the Teltonika FMC225 and is the answer not in the manual?
This document describes the process of testing the FMC225 device in RS-232 and RS-485 TCP link mode, focusing on establishing communication between the device and a server using text messages.
The FMC225 device, when configured in RS-232/RS-485 TCP Link mode, facilitates communication with an external device (such as a PC) using text messages. Any data string received via RS-232 or RS-485 is routed to a server, provided an active link is established. Messages exchanged between the FMC225 device and the server must be packed in Codec.12 format. For testing purposes, the Hercules SETUP utility is used for server-side operations (sending and receiving messages), and a Terminal application is used for sending messages from the external device to the server.
1. Configuration of FMC225: * Access the FMC225 configurator. * In the global parameters window, set the parameters for either RS-232 or RS-485, depending on the port being used. * Select the desired Baudrate for RS-232. * Set the mode to "TCP Ascii." * Configure the "Message Timestamp" parameter as needed (Enabled for Codec 13, Disabled for Codec 12). * In the GPRS data sending Settings section of the working device profile, set the Domain and Target Server Port for server communication. * Save the configuration to the FMC225 device.
2. Establishing a Test Link with Hercules (Server Side): * Connect the FMC225 device to the PC (acting as both server and external device) via RS-232 or RS-485 cables, ensuring correct RX/TX connections. * Start the Hercules SETUP utility on the PC. * Navigate to the "TCP Server" section. * Enter the server (PC) port number and click "Listen." * Monitor the "Client connection status" to confirm successful connection between the server and FMC225.
3. Sending Messages from Server to External Device via Hercules:
* In Hercules, pack the message in Codec.12 format. An example HEX format is provided: 00000000000000260C01050000001e48656c6c6f2c206c657473207465737420544350206c696e6b206d6f64650100001aef.
* Paste the packed message into the "Send" field.
* Ensure the "HEX format" box is unchecked if the text is already in HEX format.
* Click the "Send" button.
* The message will appear in the "Sent data" field (Terminal) in Hercules.
* To verify successful transmission to FMC225, check the Terminal window.
4. Sending Messages from External Device to Server via Terminal: * Connect the Port ½ cable to the RS232 RX/TX cables on the FMC225 device and the USB side to the computer. * Identify the correct COM Port for the Port ½ cable in the device manager (e.g., COM21). * Open the Terminal application. * Select the correct COM Port and click "connect." * Type the desired text message into the marked field in the Terminal application. * Press the "Send" button. * To verify data reception on the server, check Hercules. Special characters (ASCII Names) need to be marked.
This comprehensive overview covers the key aspects of using and testing the FMC225 device in RS-232/RS-485 TCP Link mode, providing a clear guide for its configuration, operation, and basic maintenance.