Page 2 of 12
OPERATION
1. Verify the power switch is in the off position. Plug your heater & thermocouple into the
rear connectors. Plug the provided line cord from the console into a standard outlet. Switch
on the console.
2. Set your desired temperature setpoint by using the up and down arrow buttons on the
TEC-9100 temperature controller.
3. Refer to the following pages for complete operation and auto-tuning of the TEC-9100 tem-
perature controller.
SPARE/REPLACEMENT PARTS
Tempco Description
Part Number
EHD-124-291 Fuse(s), rated 10 Amps/ 250V, 5 x 20mm fast acting, BUSS S501-10-R.
Used for main and heater (power located inside power cord inlet).
EHD-124-276 (for 1, 2, and 3-zone units) Fuse (1), rated 1 Amp/ 250V, ¼" x 1¼", fast acting,
BUSS ABC-1-R. Used for TEC-9100 Controller (located inside rear panel mounted
fuseholder)
EHD-124-277 (for 4-zone units) Fuse (1), rated 1 Amp/ 250V, ¼" x 1¼", slow acting, BUSS MDA-1-R.
Used for TEC-9100 Controller (located inside rear panel mounted fuseholder).
EHD-124-279 (for 2-zone units) Fuses (2), rated 5 amps, 250V, ¼" x 1¼", fast acting, BUSS ABC-5-R.
EHD-124-282 (for 3-zone units) Fuses (3), rated 4A, 250V, ¼" x 1¼", fast acting, BUSS ABC-4-R.
EHD-124-286 (for 4-zone units) Fuses (4), rated 2.5 amps, 250V, ¼" x 1¼", fast acting, BUSS ABC-2.5-R.
EHD-102-113 (for 120V units) Power output plug (1 per zone), Hubbell HBL4720C, 15A 125V Twist-Lock.
EHD-102-121 (for 240V units) Power output plug (1 per zone), Hubbell HBL4570C, 15A 250V Twist-Lock.
(Type of plug dependent on console model ordered)
TCA-101-104 Type “K” thermocouple mini plug (1 per zone), yellow
TCA-101-105 Type “J” thermocouple mini plug (1 per zone), black
TCA-101-136 Type “CU” mini-plug, white (for 2-wire RTD)
NOTE: For all fuses, use listed BUSS part numbers or equivaliant.