Accuracy Specifications(4)
33
Range Resolution
400µA
4000µA
40mA
400mA
4A
10A
Accuracy
Overload Protection
(1.5%+5)
500mA/250V fast type
fuse φ 5x20mm
0.1µA
1µA
10µA
100µA
1mA
10mA
(2%+5)
(2.5%+5)
D. AC Current
Un-Fused
Remark:
l At 10A Range: For continuous measurement 10 seconds and interval not less
than 15 minutes.
l Input impedance: approx. 10M.
l Measurement voltage drop: Full range at 400mV.
Model 72-7765: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tenma 72-7765 and is the answer not in the manual?

Tenma 72-7765 Specifications

General IconGeneral
TypeDigital Multimeter
Max Voltage600V DC/AC
Max Current10A DC/AC
Battery9V
ContinuityYes
Diode TestYes
DisplayLCD
Frequency Measurement10MHz
DC Voltage400mV to 600V
DC Current400μA to 10A
AC Current400μA to 10A