15
EN
Problem solving
Problem Possible cause Soluon
The device is plugged in,
no diodes are on.
Problem with the
connecon.
Check the connecon of
the power wire, the plug
and the socket.
Heang element is not
heang, outside diodes
are winking alternately.
Temperature sensor has
been damaged.
Disconnect the device
completely, wait unl the
radiator cools down and
then re-connect it.
Overheang of device.
Check and conrm that
the heang element's out-
put does not exceed the
recommended output of
your radiator. Check and
reduce the water tem-
perature in the central
heang system-must not
exceed 82°. In electric-only
version check, if the radi-
ator is properly lled with
the heang agent.
Heang element is heang
despite turning it o with
the on/o buon.
Damaged Electronics.
Disconnect the device
completely, wait unl the
radiator cools down and
then re-connect it.
If the problem connues please contact Your local Distributor.