- 57 -
Model No.
BCPI7
BCPI10
BCPI13
BCPI17
BCPI21
BCPI30
BCPI30
Heating Capacity at Air 26
, Humidity 80%, Water 26
in, 28
out
Heating Capacity
kW)
7.76
1.76
10.552.40
13.613.09
17.153.88
21.414.85
30.016.81
30.056.84
Power Input
kW)
1.12
0.11
1.520.15
1.950.19
2.460.24
3.080.30
4.300.42
4.300.42
COP
15.75
6.94
15.846.95
16.126.98
15.966.98
15.956.96
16.116.98
16.146.99
Heating Capacity at Air 15
, Humidity 70%, Water 26
in, 28
out
Heating Capacity
kW)
5.761.30
7.851.78
10.122.29
12.782.89
15.913.59
22.054.98
22.144.99
Power Input
kW)
1.160.17
1.580.23
2.030.30
2.570.38
3.200.47
4.430.65
4.440.65
COP
7.574.96
7.594.97
7.644.99
7.634.98
7.594.97
7.624.98
7.634.99
Cooling Capacity at Air 35
, Water 29
in, 27
out
Cooling Capacity
kW)
4.281.06
5.921.48
7.251.82
9.472.35
11.582.96
15.863.91
15.893.93
Power Input
kW)
1.15
0.16
1.57
0.22
1.89
0.26
2.51
0.34
3.07
0.43
4.18
0.56
4.17
0.56
EER
6.61
3.73
6.74
3.76
6.95
3.83
6.89
3.78
6.87
3.77
6.94
3.79
6.98
3.81
Power suply
220
240V / 1/ 50 Hz
380
415V / 3/
50 Hz
Rated Power Input
kW)
1.2
1.6
2.1
2.6
3.2
4.4
4.4
Rated Current(A)
5.4
7.3
9.4
11.7
14.6
20.1
7.9
Compressor
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
Refrigerant
R32
R32
R32
R32
R32
R32
R32
Heat Exchanger
Titanium
Titanium
Titanium
Titanium
Titanium
Titanium
Titanium
Air Flow Direction
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Water Flow Volume
m
3
/h)
2.5
3.5
4.5
5.5
6.5
9
9