Table 1: Guidance and Manufacturer’s Declaration Electromagnetic Emission
T-SEAL III is intended for use in the electromagnetic environment specified below. The customer or
the user of T-SEAL III should assure that it is used in such an environment.
Emission Test
Compliance
Electromagnetic Environment Guidance
RF emission
CISPR 11
Group 2
T-SEAL III must emit electromagnetic energy in order to
perform its intended function. Nearby electronic equipment
may be affected.
RF emission
CISPR 11
Class B
T-SEAL III is suitable for use in all establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies
buildings used for domestic purposes.
Harmonic emission
IEC 61000-3-2
Class A
Voltage fluctuations/
Flicker emissions
IEC 61000-3-3
Complies
Table 2: Guidance and Manufacturer’s Declaration Electromagnetic Immunity
T-SEAL III is intended for use in the electromagnetic environment specified below. The customer or
the user of T-SEAL III should assure that it is used in such an environment.
Immunity Test
IEC 60601
Test Level
Electromagnetic
Environment Guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
± 8 kV contact
± 15 kV air
15 kV
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
± 2 kV for power
supply lines
Mains power quality should be that of a
typical commercial or hospital
environment.
Surge
IEC 61000-4-5
± 1kV line(s)
to line(s)
± 2kV line(s)
to earth
2kV
Mains power quality should be that of a
typical commercial or hospital
environment.
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
< 5% Uτ
(> 95% dip in Uτ)
for 0.5 cycle
40% Uτ
(60% dip in Uτ)
for 5 cycles
70% Uτ
(30% dip in Uτ)
for 25 cycles
< 5% Uτ
(> 95% dip in Uτ)
for 5 sec
(> 95% dip in
Uτ)
for 0.5 cycle
40% Uτ
(60% dip in Uτ)
for 5 cycles
70% Uτ
(30% dip in Uτ)
for 25 cycles
< 5% Uτ
(> 95% dip in
Uτ)
Mains power quality should be that of a
typical commercial or hospital environ-
ment. If the user of the T-SEAL III
requires continued operation during
power mains interruption, it is re-
commended that the T-SEAL III be
powered from an uninterruptible power
supply or battery.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m
Power frequency magnetic fields should
be at levels characteristic of a typical
location in a typical commercial or
hospital environment.
NOTE Uτ is the
AC mains voltage