HAZARDOUS LOCATIONS CERTIFICATIONS
Factory Mutual (FM) Approval:
Explosion Proof
Identification No. 2Z0A0.AE
Class I, Division I, Groups B, C, and D
Enclosure type 4X
SPECIAL CONDITIONS FOR SAFE USE
-20°C T
amb
60°C
Do not remove cover while circuits are live
Installation to be in accordance with the latest edition of
National Electrical Code
Unused conduit entry must be closed with suitable blanking
element
Seal conduit within 18 inches
Canadian Standards Association (CSA)
Explosion proof
Certification No. LR 85614-4
Class I, Groups B, C, and D
Enclosure Type 4X
SPECIAL CONDITIONS FOR SAFE USE
-20°C T
amb
60°C
Do not remove cover while circuits are live
Installation to be in accordance with the latest edition of
Canadian Electrical Code
Rated 24 VDC, 350 mAmps
Maximum working pressure: 110 PSIG
KEMA/Cenelec
Flameproof Certification
Certificate No. KEMA 03ATEX2365
ATEX Marking: EEx d IIB + H
2
T4
Category: II 2 G
Enclosure type IP65
SPECIAL CONDITIONS FOR SAFE USE
-20°C T
amb
60°C
Do not remove cover while circuits are live
Installation to be in accordance with the applicable local
requirements
The cable and conduit entry devices shall be of certified
flameproof types, suitable for the conditions of use and
correctly installed
Unused apertures shall be closed with certified flameproof
blanking elements