ER3000 INSTALLATION ER3000
FLOW CHART WIRING DIAGRAM
The following tables give the complete
wiring layout of the ER3000 wiring
assemblies, which are connected to
the J3 and J4 terminal blocks. Refer to
the tables to ensure proper wiring of
external devices.
Note: The (+) and the (-) refer to the
differential inputs. Both must be
connected for the system to work properly.
Table 1: Main Cable Assembly*
Table 2: Auxiliary Cable Assembly
(ER3000F/ER3000G)
7
J3 Pins Description Color
1 +Setpoint Input Brown
2 -Setpoint Input Red
3 +Feedback Input Orange
4 -Feedback Input
Yellow
*
5 -RS485 Network connection Green
6 +RS485 Network connection Blue
7 + 24 Volt DC Power Violet
8
24 Volt Return, (Power Ground)
Gray
9 +5 Volt output (5mA max.) White
10 Analog Signal Ground Black
11 Analog Signal Output Pink
12 Analog Signal Ground Tan*
J4 Pins Description Color
1 +Auxiliary Input #1 Brown
2 -Auxiliary Input #1 Red
3 +Auxiliary Input #2 Orange
4 -Auxiliary Input #2 Yellow
5 Analog Signal Ground Green
6 Analog Output Ground Black
7 Digital Output #1 Blue
8 Digital Output #2 White
Step 1: Select Voltage/Current
Jumper J5 (top board see below
right for Figure 1) – Select Jumper
position* for:
1: Analog Setpoint
2: External Feedback
3: Auxiliary input #1
4: Auxiliary input #2
For all the above jumper positions:
Jumper not installed:
configured for 1-5V.
Jumper installed: configured
for 4-20mA.
*Not on 0-10V models
Step 2: Plumb the external
regulator and transducer
Use safety information on pages
4-6 & 8-10 prior to pressurization
and operation of all equipment.
Step 3: Mount the ER3000
Four 8-32 UNC screw holes are
provided.
Step 4: Electrical wiring
Connect ER3000 to a power supply,
transducer, and computer (if needed),
using the tables on this page.
Note: All electrical wiring must be
in accordance with applicable local
standards (see pages 4-6 & 8-10).
Step 5: Tune program (if using
a computer)
Download the Tune program onto
your computer.
Step 6: Read
and follow the
safety sections on page 4-6
& 8-10 carefully prior to
pressurization and operation
of the system.
Figure 1: Top Board
J3 & J4 Terminal
Blocks
J5 Jumpers
*
The tan wire should be connected to the yellow
wire in systems with 4-20mA feedback.

Other manuals for Tescom ER3000