EasyManua.ls Logo

Tesmed MAX 830 User Manual

Tesmed MAX 830
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ATTENTION
Beforeuse,readcarefullytheusermanual,payingattentiontothe
warningsandcontraindicationslistedinit.
UseonlyTesmedelectrodesastheyareconstructedwithmaterialsabletoguarantee
maximumconductivityofthepulsesofourelectrostimulators.
Thelargerelectrodesarepositionedinthesamewayasthesmallerones.
Ifthecablesareabithardtoinsertintothedevice,youcantrytograduallyforcethe
insertion.
Incaseoflackofstimulationorothermalfunctions,checktheconditionofthe
electrodesandtheiradhesiontotheskin,thecorrectconnectionofallthepartsand
possiblythebatterycharge.
Youcancustomizetheuseofyourstimulator:
1.usinglesschannels;
2.usingTesmedelectrodesofdifferentsizes;
3.usingyourfavoriteprogramintheareayouwishtotreat,regardlessoftheindication
inthemanual.Forexample,theabdomentoningtreatmentcanwellbeperformedon
anotherarea,suchaslegs,pectorals,gluteus,etc…
Youcanuseyourfavoriteprogramonmultiplezones.Youcannotsettwodifferent
programsatthesametime.
REMEMBER
Programs21to99arepresetwithdifferentstimulationsteps.
Eachphasealternatesmomentsofactivitywithmomentsofrest.Itisnotpossibletoincrease
theintensityduringthemomentofrest.So,donotincreasetheintensityintherestphases
duringprogramexecution,butonlyduringactivephases.
Ifyoukeepalowintensity,forexampleatlevel1orlevel2,atthephasetransitionduring
execution,theprogrammaybereset.Inthiscase,restartwiththeprogramandkeepthe
intensityabithigher.
Youmayhavetheperceptionthatontheonesidetheimpulsesarelessintense.Thestimulator
emitsthesameimpulsesonallchannels,soprobablyyouhavenotwellidentifiedthemotor
pointsofthemuscle,orononesidethereismorefattissue,ortheelectrodesarewornout.Try
movingtheelectrodes,makingsuretheyarewelladherenttotheskin.
Thelevelofintensitytoachievethedesiredmusclecontractioncanvarydependingonmultiplefactors,
includingtheplacementoftheelectrodesandthepresenceofadiposetissue.
Therefore,thesamecurrentintensitycanprovidedifferentsensationsfrompersontoperson,
fromdaytoday,fromtheleftsidetotherightside.
Ifyouneedtechnicalassistancewritetoinfo@tesmed.com,orcall00390305050163
fromMondaytoFridayfrom09.00to16.30,excludingholidays.
Wesolve100%ofrequestsquicklybecauseourpriorityiscustomersatisfaction.
Beforeuse,readcarefullytheusermanual,payingattentiontothewarningsand
contraindicationslistedinit.
QUICKUSERGUIDEANDUSEFULTIPS
Batteryalreadyinserted,devicereadytouse.Ifthebatterysymbolflashesafterswitchingon,charge.
1.Connectthe4
bipolarcables
2.Inserttheelectrodesinthecablesand
placethemonthetreatmentarea
Youmayrefertotheelectrodes
placementphotosinthemanual
EQUIPMENTDESCRIPTION
LCDdisplayandkeys
1Tesmedlogo
2Programnumber
3Programsymbol
4Lowbatterysymbol
5Frequencysymbol
6Selectedoutputchannels(n.4)
7Relativeintensityvalueforeach
4output
8Functionskey(MODE)
9Decreasekey()
10Increasekey()
11ON/OFFandselectchannels
doublefunctionkey
12Intensitysymbol
13KeyboardblockandONblock
symbol
14Timersymbol
15Treatmenttimeandremaining
time
16Clocksymbol
17Outputchannels
18Batteryrechargersocket
19Batterydoor
20Removablebelthook
Thebatteryisalreadyinstalledinthedevice.
IftheflashingbatterysymbolappearsonthedisplayortheTesmeddoesnot
lightup,chargethedevice.Whenthesymbolstopsflashingordisappears,the
batteryischarged.IfthebatteryischargedandtheTesmedisconnectedto
thebatterycharger,theTesmedscreenwillnotlightupandnosignalwill
appearbecausethebatterychargerdetectsthatthereisnoneedforcharging
andthereforedoesnotactivate.
4
1

Other manuals for Tesmed MAX 830

Question and Answer IconNeed help?

Do you have a question about the Tesmed MAX 830 and is the answer not in the manual?

Tesmed MAX 830 Specifications

General IconGeneral
CategoryMedical Equipment
TypeElectrotherapy Device
ModelMAX 830
Number of Channels2
Power SourceBattery
TechnologyTENS/EMS
DisplayLCD
ParametersPulse Width, Frequency, Intensity
Power SupplyAAA batteries

Summary

Attention and General Usage

General Precautions and Usage Tips

General usage guidelines, electrode care, device connection, and operational tips for the Tesmed stimulator.

Quick User Guide

Device Setup and Initial Operation

Steps for connecting cables, placing electrodes, and initial device setup for treatment.

Equipment Description

Overview of the Tesmed device's LCD display, keys, and physical components.

Device Use Mode

Switching On and Program Selection

Instructions for powering on the Tesmed device and selecting treatment programs.

Treatment Customization: Time and Frequency

Guide to adjusting treatment time and frequency for specific programs (01-20).

Intensity Adjustment and Controls

How to adjust intensity levels, manage phase transitions, and control individual channels.

Error Handling and Troubleshooting

Troubleshooting steps for electrode disconnection errors and device reset procedures.

Device Functions: Keyboard and ON Block

Explanation of the keyboard lock and accidental power-on prevention features.

Related product manuals