EasyManua.ls Logo

Tetra EX 600 Plus - Servicing the filter; Servicing preparations

Tetra EX 600 Plus
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English translation of the original German instructions
18
WARNING
Danger of death from electric shock.
Use a correctly installed socket to supply
power.
Check the filter, hoses, mains cable and
mains plug for visible signs of damage.
Do not insert the plug in the socket if there is
any damage.
ATTENTION!
Risk of damage to the filter caused by dry
running of the pump. The pump will run as
soon as the filter is connected to the power
supply.
Make sure that the pump never runs dry.
Insert the mains plug in a correctly installed socket
(230 V ~ 50 Hz) to supply power.
ATTENTION!
Risk of water damage caused by leak
s in the
hoses and connectors.
Immediately after the filter is started, check
all the hoses and connectors for leaks.
If you discover a leak, pull out the mains
plug immediately.
Do not put the filter back into operation until
the leak has been eliminated.
Repeat the leak test after approx. 30
minutes in operation.
You can regulate the water flow by turning the valves.
Servicing the filter
Servicing intervals
Inspection
Cleaning
Replacement
Tetra FF
fine filter -
fleece
Once a
month
Tetra CF
carbon filter
medium
Every 24
weeks
Tetra BB bio
filter balls
Every 12
months
When -
blocked by
extreme -
soiling
When dirt on
the surface -
cannot be
removed by -
rinsing
Tetra BF
biological
filter foam
Every 6
months
When the
inspection -
reveals -
soiling
Every 12
months
Tetra CR
ceramic filter
rings
Every 12
months
When
blocked by
extreme -
soiling
When dirt on
the surface -
cannot be
removed by -
rinsing
Impeller
When the
motor does
not run or
the flow of
water is
reduced
Servicing preparations
WARNING
Danger of death from electric shock.
Pull out the mains plug before carrying out
any work on the filter.
Never reach into the water when the filter is
connected to the mains supply.
Pull out the mains plug.
Close the two valves (1).