EasyManuals Logo

Texas Instruments CC2541EMK Software Developers Guide

Texas Instruments CC2541EMK
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #127 background imageLoading...
Page #127 background image
www.ti.com
Client Commands
127
SWRU271H–October 2010–Revised April 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
GATT/ATT API
bStatus_t GATT_ReadUsingCharUUID ( uint16 connHandle, attReadByTypeReq_t *pReq, uint8
taskId )
Used to read a Characteristic Value from a server when the client only knows the
characteristic UUID and does not know the handle of the characteristic.
Parameters connHandle: connection to use
pReq: pointer to request to be sent
taskId: task to be notified of response
Notes If the return status is SUCCESS, the calling application task receives an OSAL
GATT_MSG_EVENT message with type ATT_READ_BY_TYPE_RSP or
ATT_ERROR_RSP (if an error occurred on the server). This sub-procedure is complete
when either ATT_READ_BY_TYPE_RSP (with SUCCESS or bleTimeout status) or the
calling application task receives the ATT_ERROR_RSP (with SUCCESS status).
bStatus_t GATT_ReadLongCharValue ( uint16 connHandle, attReadBlobReq_t *pReq, uint8
taskId )
Used to read a Characteristic Value from a server when the client knows the
Characteristic Value Handle and the length of the Characteristic Value is longer
than can be sent in a single Read Response Attribute Protocol message.
Parameters connHandle: connection to use
pReq: pointer to request to be sent
taskId: task to be notified of response
Notes If the return status is SUCCESS, the calling application task receives multiple
GATT_MSG_EVENT messages with type ATT_READ_BLOB_RSP or
ATT_ERROR_RSP (if an error occurred on the server). This sub-procedure is complete
when either ATT_READ_BLOB_RSP (with bleProcedureComplete or bleTimeout status)
or the calling application task receives the ATT_ERROR_RSP (with SUCCESS status).
bStatus_t GATT_ReadMultiCharValues ( uint16 connHandle, attReadMultiReq_t *pReq, uint8
taskId )
Used to read multiple Characteristic Values from a server when the client knows
the Characteristic Value Handles.
Parameters connHandle: connection to use
pReq: pointer to request to be sent
taskId: task to be notified of response
Notes If the return status from this function is SUCCESS, the calling application task receives
an OSAL GATT_MSG_EVENT message with type ATT_READ_MULTI_RSP or
ATT_ERROR_RSP (if an error occurred on the server). This sub-procedure is complete
when either ATT_READ_MULTI_RSP (with SUCCESS or bleTimeout status) or the
calling application task receives the ATT_ERROR_RSP (with SUCCESS status).

Table of Contents

Other manuals for Texas Instruments CC2541EMK