EasyManua.ls Logo

Texas Instruments MSP430x1xx - Page 246

Texas Instruments MSP430x1xx
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Timer_B Operation
12-12
Timer_B
Figure 12−11.Capture Cycle
Second
Capture
Taken
COV = 1
Capture
Taken
No
Capture
Taken
Read
Taken
Capture
Clear Bit COV
in Register TBCCTLx
Idle
Idle
Capture
Capture Read and No Capture
Capture
Capture ReadCapture
Capture Initiated by Software
Captures can be initiated by software. The CMx bits can be set for capture on
both edges. Software then sets bit CCIS1=1 and toggles bit CCIS0 to switch
the capture signal between V
CC
and GND, initiating a capture each time
CCIS0 changes state:
MOV #CAP+SCS+CCIS1+CM_3,&TBCCTLx ; Setup TBCCTLx
XOR #CCIS0,&TBCCTLx ; TBCCTLx = TBR
Compare Mode
The compare mode is selected when CAP = 0. Compare mode is used to
generate PWM output signals or interrupts at specific time intervals. When
TBR counts to the value in a TBCLx:
- Interrupt flag CCIFG is set
- Internal signal EQUx = 1
- EQUx affects the output according to the output mode

Table of Contents