ADC10 Operation
18-9
ADC10
18.2.6 Conversion Modes
The ADC10 has four operating modes selected by the CONSEQx bits as
discussed in Table 18−1.
Table 18−1.Conversion Mode Summary
CONSEQx Mode Operation
00 Single channel
single-conversion
A single channel is converted once.
01 Sequence-of-
channels
A sequence of channels is converted once.
10 Repeat single
channel
A single channel is converted repeatedly.
11
Repeat sequence-
of-channels
A sequence of channels is converted
repeatedly.