Premier 412/816/832 Master User Manual User Functions Menu
INS141-6 13
Change User Code
All users of the alarm system can change their own Access
code number.
" To change your Access code, proceed as follows:
YES to Arm?
MENU for Options
Code : ******
Enter new code
If the code is 4 or 5 digits the / key to
accept.
????
aypress
Enter N5
Enter Access code ????
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Code : ****
Armed
Zones
87654321
Ready
Alarm
Service
4
5
The keypad will sound an acceptance tone if the new
Access code was accepted. If you hear an error tone
(low), please repeat from step 1.
Armed
Zones
87654321
Ready
Alarm
Service
Re-enter new code ????
View Log (LCD Only)
The control panel has an Event Log, which stores all system
activity i.e., users entering their codes to arm and disarm the
system, alarm events, faults etc. Each event is time and date
stamped. The number of events stored in the control panel
is as follows:
Premier 412 - 750 events
Premier 816 - 750 events
Premier 832 - 1000 events
" To view the Event Log, proceed as follows:
Bedroom 1 PA
1... 13:15.56 28
Day
Event Type
(showing Zone Text)
TimePartitions Day/Month
Event Type
(Alarm Type & Zone No)
Time
PA Aud 02 Alm
13:15.56 28/04
Press to toggle
information displayed
A
YES to Arm?
MENU for Options
Enter N6
Enter Access code ????
1
2
3
4
Press to scroll up and down through the log.
Press to when finished.
U
N
Abort Communications
This option aborts any communications to the Alarm
Receiving Centre.
" To Abort Communications, proceed as follows:
The keypad will bleep and the alarm system will abort
all communications to the Alarm Receiving Centre.
Enter N7
Enter Access code ????
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Premier 816
17:30.21 28/04
Armed
Zones
87654321
Ready
Alarm
Service
YES to Arm?
MENU for Options
,

Table of Contents