INS159-13
P
r
emier 412/816/832
I
nstalla
tion M
anual
2
Table of Contents
Premier 412/816/832 Installation Manual
2
Default Chapter
2
Table of Contents
2
System Architecture
5
Control Panels
5
Remote Keypads
5
System Overview
5
Zone Expansion Modules
6
Installation
7
PC-Com Module
6
Comip Module
6
Speech Module
6
Radio Receiver Module
6
Installation Sequence
7
Control Panel
7
Mounting
7
Wiring the Control Panel
7
Control Panel PCB Layout
8
Power Supply Ratings
9
All Models (Large & Small Polymer)
9
All Models (Metal)
9
Connecting AC Mains
10
Connecting Devices to the Data Bus
10
Wiring the Data Bus
10
Cable Type and Distances
10
Installing a Power Supply
10
Overcoming Voltage Drop
11
Use of Pull up Resistors
11
Installing Remote Keypads
12
Keypad Layouts
12
Remote Keypad Connections
12
Remote Keypad Address
12
Keypad Zones
12
Keypad Output
12
Keypad Speaker Output (LCDL/LCDLP FMK/SMK)
13
Adjustable Backlighting
13
Keypad Lid Tamper
13
Remote Zone Expander Module
13
Remote Expander Layout
13
Wiring the Zone Expander
13
Remote Expander Address
13
Remote Expander Zones
13
Zone Expander Outputs
14
Zone Expander Speaker Driver
14
Local Zone Expander Module
14
Local Expander Layout
14
Local Expander Zones
14
Installing the Local Zone Expander
14
Zone Connections
15
Normally Closed
15
Normally Open
15
Single EOL - N/C & N/O (Burglary)
16
Single EOL - N/O (Fire)
16
Single EOL - N/C
16
Single EOL - O/C Tamper
16
Single EOL - S/C Tamper
16
Double EOL
17
Zone Doubling
17
Triple EOL
17
Double Pole
18
2-Wire Smoke Detector
18
Speaker/Bell Connections
18
Speaker Operation
18
Siren/Bell Operation
19
Siren/Spk Supervision
19
Telephone Line Connections
19
Commissioning & Troubleshooting
20
Panel Outputs 1 - 8
19
Output Wiring
19
Output Supervision
19
Commissioning
20
Troubleshooting
20
Power Faults
20
Remote Keypads
20
Remote Expander
20
Zones
21
Service Faults
21
Communicator
21
Operation
21
Introduction
22
Viewing Numeric Data (LED Keypads)
22
Programming Text (LCD Only)
22
Programming the Control Panel
22
V16 Start up Procedure
23
Premier RKP8 & 16 LED Keypads
23
Premier LCD Keypads
23
Program Menus
24
Programming Zones
25
All Zone Options
26
Zone Type
26
Zone Wiring
27
Zone Attributes 1
27
Zone Attributes 2
28
Zone Attributes 3
28
Zone Attributes
28
Zone Attributes 3 (Key Switch)
29
Zone Partitions & Groups
29
Zone Text (LCD Only)
29
Assign Radio Device
29
Zone Attributes
29
Zone Text
29
Programming Partitions
30
Partition Exit Delay
31
Partition Entry Delay 1
31
Partition Entry Delay 2
31
Partition Communication Delay
31
Partition Bell Delay
31
Partition Bell Duration
31
Partition Options
31
Partition Entry Delay 1 Time
31
Partition Entry Delay 2 Time
31
Partition Communicator Delay
31
Partition Auto Arm/Disarm Options
32
Equipment Areas
32
Partition Auto Arm/Disarm
32
Programming Global Options
33
System Timers
35
System Control Timers
35
System Counter/Levels
36
System Control Timers
36
System Options 2
37
System Options 3
37
System Options
37
Hardware Options
38
Auxiliary Input Options
38
Miscellaneous Options 1
38
Miscellaneous Options 2
39
Miscellaneous Options 3
40
EN50131 Options
40
Miscellaneous Options
40
Programming Remote Keypads
41
Keypad Options 1
42
Keypad Options 2
42
Keypad Options 3
42
Keypad Options
42
Keypad Options
43
Programming Remote Expanders
44
Expander Partitions
44
Expander Tones
44
Expander Volume Level
44
Programming System Outputs
45
Panel Outputs
47
Fast Format/Speech Channels
47
Expander 1 Outputs
47
Expander 2 Outputs
47
Expander 3 Outputs
47
Keypad Outputs
47
Output Groups and Types
47
Output Attributes
49
Programming the Communicator
50
Communicator Options
52
ARC 1 Communicator Menu
52
Telephone Numbers
52
Account Numbers
53
Protocol Type
53
Dial Attempts
53
Partition Options
53
Reporting Options
54
Pulse Format Options
54
Fast Format Reporting Channels
54
Protocol Options
55
ARC 2 Communicator Options
55
Fast Format Restore Channels
55
Fast Format Open/Close Channels
56
Cancel Call Waiting Sequence
56
Programming Check List
57
Programming Download Options
58
Download Menu
60
Download Options
60
Call Back Number
60
UDL Passcode
60
Download Dial Attempts
60
Ring Count
60
Com1 Device Type
60
IP Address & Port
61
Comip Gateway Address
61
Comip Subnet Mask
61
Com2 Device Type
61
Chiron Iris Data Setup
61
Programming Reporting Codes
62
Zone Alarm/Restore Codes
63
Zone Bypass/Unbypass Codes
63
Non Zone Alarm/Restore Codes
63
Contact ID and SIA Codes
63
Programming Users
64
Program User
66
User Options 1
66
User Options 2
66
User Options 3
67
User Text (LCD Only)
67
Program Standard Users
67
Default ALL Users
67
System Tests & Utilities
68
Walk Test
69
Test Speakers & Outputs
69
Send Test Call
69
Enable Remote/Engineer Access
69
Start Call Back
69
Program Time
69
Program Date
69
Program Banner Text (LCD Only)
69
Print 100 Events
69
Log off Engineer
69
Introduction
70
Access Codes
70
Operating the Alarm System
70
Arming & Disarming the Alarm System
70
Checking if the System Is Ready to Arm
70
Away Arming
70
Stay Arming
70
Cancelling the Arming Process
71
Disarming During Entry
71
Disarming When Not in Entry
71
Disarming after an Alarm
71
Auto Stay Arming
71
Changing between Delayed and Instant Stay
71
Arming and Disarming Partitions
72
Away Arming Partitions
72
Stay Arming Partitions
72
Disarming Partitions
72
Changing to Another Partition
73
Bypassing Zones
73
Manually Bypassing Zones
73
Unbypassing Zones
73
Group Bypass
74
Quick Bypass and Arm
74
Last Alarm Log
75
Service Faults
75
Acknowledging a New Service Fault
75
View Service Faults
76
Ins159
76
Reset Alarms
75
Toggle Chime on and off
77
Change User Code
77
View Log (LCD Only)
77
Abort Communications
77
Specifications
78
Anti-Code Reset
77
Control Panel
78
All Models Large & Small Polymer
78
All Models Metal
78
Standards
79
EN 50131-1/3/6 Compliance
79
Remote Zone Expander
79
Safety Notes
79
Local Zone Expander
79
Remote Keypads
79
Warranty
80
Quick Reference Guide
81
Standard Defaults & Programming Records
86
Installation Details
86
Zone Details
86
Programming Worksheets & Defaults
87
Notes
99
Other manuals for Texecom Premier 412
User Manual
24 pages
Programming Guide
8 pages
Master User Manual
24 pages
User Guide
24 pages
Need help?
Do you have a question about the Texecom Premier 412 and is the answer not in the manual?
Ask a question
Texecom Premier 412 Specifications
General
Type
Control Panel
Zones
4
Keypads
Up to 8
Part Sets
4
Communication
IP, GSM
Battery Backup
7Ah
Compatible with
Texecom peripherals
Dimensions
80mm
Related product manuals
Premier 412 Premier 816 Premier 832
20 pages
Texecom PREMIER 48
64 pages
Texecom Premier Elite 48-W
12 pages
Texecom Premier 24
64 pages
Texecom PREMIER 88
64 pages
Texecom Premier 816
24 pages
Texecom Premier 888
42 pages
Texecom Premier 8SP
24 pages
Texecom PREMIER 168
64 pages
Texecom Premier Elite 24
12 pages
Texecom Premier Elite 64-W
152 pages
Premier Elite Micro Contact-W
25 pages