Premier 412/816/832 Installation Manual Quick Reference Guide
INS159-13 81
7. Quick Reference Guide
Menu
Function
Page
Programming Zones

All Zone Options
26

Zone Type
26
 Null
 Delay 1
 Delay 2
 Interior Follower
 Interior Instant
 Perimeter Instant
 Fire
 PA Silent
 PA Audible
 Medical
 24-Hour Tamper
 Trouble
 24-Hour - Gas
 24-Hour - Water
 24-Hour - High Temp
 24-Hour - Low Temp
 Momentary Key Switch
 Maintained Key Switch
 Push To Set

Zone Wiring
27
Normally Closed
Normally Open
Single EOL - N/C & N/O
Single EOL - N/O (Fire)
Single EOL - N/C
Single EOL - O/C Tamper
Single EOL - S/C Tamper
Double EOL
Zone Doubled
Triple EOL

Zone Attributes 1
27
Enable Instant Internals
Enable Bell
Delayed Bell
Pulsed Bell
Enable Instant Strobe
Enable User Chime
Enable Transmission Delay
Enable Transmission

Zone Attributes 2
28
Enable Manual Bypass
Enable Stay Bypass
Enable Force Arming
Quick Response Time
Enable Cross Zoning
Enable Soak Test
Enable Swinger Shutdown
Enable Double Knock

Zone Attributes 3
28
Change to Delay 1 on Stay Arm
Change to Follower on Stay Arm
Zone Warning (* Keyswitch is Instant Arming)
Auto Reinstate if Force Armed (* Keyswitch will Stay Arm/Disarm)
Disable Keyswitch if Away Armed
Disable Exit Faults (* Disabled Auto Arm)
Truncate Exit Delay (* Monitor Only)
Forced Walk Test
* Attributes for Key Switch zone types

Zone Partitions & Groups
28
Enabled for Partition 1
Enabled for Partition 2
Enabled for Partition 3
Enabled for Partition 4
Enable for Bypass Group 1
Enable for Bypass Group 2
Enable for Bypass Group 3
Enable for Bypass Group 4

Zone Text
29
. , ? ! 1 @ ” - &
a b c 2 A B C
d e f 3 D E F
g h I 4 G H I
j k l 5 J K L
m n o 7 M N O
p q r s 7 P Q R S
t u v 8 T U V
w x y z 9 W X Y Z
Space 0 , # *
Move Left/Right
Backspace (delete)

Assign Radio Device
29
Menu
Function
Page
Programming Partitions

Partition Exit Time
31

Partition Entry Delay 1 Time
31

Partition Entry Delay 2 Time
31

Partition Communicator Delay
31

Partition Bell Delay
31

Part Bell Duration
31

Partition Options
31
Enable Auto Bypass Mode
Stay Armed Exit is Silent
Enable Remote Arming
Enable Remote Disarming
Enable Local Exit Tones
Stay Armed Entry is Instant
Stay Armed Exit is Delayed
Only Start Exit when Partition is Ready

Partition Auto Arm/Disarm
32
Arm with Control Timer 1
Arm with Control Timer 2
Arm with Control Timer 3
Arm with Control Timer 4
Disarm with Control Timer 1
Disarm with Control Timer 2
Disarm with Control Timer 3
Disarm with Control Timer 4

Equipment Areas
32
Auxiliary Input Areas
Panel Bell Areas
Bell Squawk Areas
Masked when Armed
Programming Global Options

System Timers
35
 AC Fail Delay
 Line Fault Delay
 Cross Zone Time
 Zone Soak Test Time
 Restore Reporting Delay
 Output Short Pulse Time
 Zone Response Time
 Transmission Abort
 Test Transmission Time
 Courtesy Delay
 Service Timer
 2-Wire Verified Delay
 Alarm Confirmation Delay
 Activity Time Window
 Poll IP Every

System Counters/Levels
36
Swinger Shutdown Count
Panel Speaker Volume
Chime Volume
Clock Adjustment
Language Selection
Country Operation Code

System Control Timers
36

System Options 1
36
Clock = Crystal
Battery Connection Supervision
Battery Dynamically Load Tested
Panel NVM is Locked
Power Savings During AC Mains Failure
Line Fault Overrides Bell Delay
Two-Wire Smoke Detection on O/P 1
Convert Siren Output from Voltage to Speaker Driver

System Options 2
37
Tamper Alarms Cause a Trouble While Disarmed
Tamper Alarms Cause a Trouble While Stay Armed
Defer Reporting of Non-Zone Restorals