EasyManua.ls Logo

Texecom Premier 412 - Walk Test; Test Speakers & Outputs; Send Test Call; Enable Remote;Engineer Access

Texecom Premier 412
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 69
Premier 816
Banner et

Premier 816
^anner et


Walk Test 
The Walk Test feature can only be performed when the partition is
disarmed. 24 hour zones (except Fire, Tamper and Trouble) are
disabled during Zone Test allowing Audible PA buttons, Silent PA
buttons, etc. to be tested.
Pressing Reset clears all previously tested zones.
Test Speakers & Outputs 
This menu options allows you to perform the following tests:
Test Speakers
Test Bells
Test Strobes
Test System Outputs
Test LCD Display
Only outputs with the ‘Enable User Test’ option selected (see
page 49), will be included in test 4.
Send Test Call 
This menu options allows you to send a test call transmission to
your Alarm Receiving Centre. If the engineer code is used to select
this option the keypad will display the progress status of the call.
If the panel is fitted with a Speech Module, keys -
can be used to switch between speech message 1 - 4 during
the test.
Enable Remote/Engineer Access 
This option will enable both Remote Access to the control panel via
downloading and Engineer Access (if EN 50131-1 requirements is
enabled, see page 37). Once enabled, the control panel will allow
access until 12.00am, after which, both Remote and Engineer
Access will be disabled.
If the “Load Defaults” jumper pins (JP6) are shorted whilst
this menu option is selected, the Engineer Access code is
restored to its factory default setting of 1234 (providing the
NVM is not locked).
Start Call Back 
This option will cause the control panel to initiate a call back
sequence. This will allow the remote downloading computer to
remotely access the control panel.
If the Call Back is unsuccessful the keypad will sound the
Error Tone.
Program Time 
The control panel has a real time clock that is used to date and time
stamp events that are recorded within the system log. The option
allows you to set the control panel time.
Program Date 
The control panel has a real time clock that is used to date and time
stamp events that are recorded within the system log. The option
allows you to set the date on the control panel.
Program Banner Text (LCD only) 
If the system is fitted with a LCD remote keypad you can assign up
to 16 characters of text to the Banner Message. The Banner
Message is displayed on the top line of the LCD display during the
normal disarmed state. Text is programmed in a similar way to
mobile phones. Characters are selected by pressing the
corresponding key the appropriate number of times (to select a
character on the same key, press to move the cursor along).
For details on entering text, see page 22.
Print 100 Events 
This menu option allows the last 100 events in the system Event Log
to be sent to the printer port (Com1).
Log Off Engineer 
Selecting this menu option will log you out of engineer’s
programming mode and return the system to its normal state.

Table of Contents