EasyManua.ls Logo

Texecom Premier 412 - Programming Worksheets & Defaults

Texecom Premier 412
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 412/816/832 Installation Manual Programming Worksheets & Defaults
INS159-13 87
Programming Worksheets & Defaults
These worksheets and defaults apply to the following control panels where standard factory defaults are loaded, if you load country defaults as
per page 36 the defaults shown may differ.
Premier 412/816 - Software Version 12.x >
Premier 832 - Software Version 12.x >
Zone Programming
Menu: 
Zone Types
Page 25
Zone
Type
Default
Zone
Type
Default
Zone Types
01
[ ] [ ]
01 (Delay 1)
17
[ ] [ ]
00 (Null)
00: Null
01: Delay 1
02: Delay 2
03: Interior Follower
04: Interior Instant
05: Perimeter Instant
06: Fire
07: PA Silent
08: PA Audible
09: Medical
10: 24-Hour Tamper
11: Trouble
12: 24-Hour - Gas
13: 24-Hour - Water
14: 24-Hour - High Temp
15: 24-Hour - Low Temp
16: Momentary Keyswitch
17: Maintained Keyswitch
18: Push To Set
02
[ ] [ ]
03 (Interior Follower)
18
[ ] [ ]
00 (Null)
03
[ ] [ ]
05 (Perimeter Instant)
19
[ ] [ ]
00 (Null)
04
[ ] [ ]
05 (Perimeter Instant)
20
[ ] [ ]
00 (Null)
05
[ ] [ ]
05 (Perimeter Instant)
21
[ ] [ ]
00 (Null)
06
[ ] [ ]
05 (Perimeter Instant)
22
[ ] [ ]
00 (Null)
07
[ ] [ ]
05 (Perimeter Instant)
23
[ ] [ ]
00 (Null)
08
[ ] [ ]
05 (Perimeter Instant)
24
[ ] [ ]
00 (Null)
09
[ ] [ ]
00 (Null)
25
[ ] [ ]
00 (Null)
10
[ ] [ ]
00 (Null)
26
[ ] [ ]
00 (Null)
11
[ ] [ ]
00 (Null)
27
[ ] [ ]
00 (Null)
12
[ ] [ ]
00 (Null)
28
[ ] [ ]
00 (Null)
13
[ ] [ ]
00 (Null)
29
[ ] [ ]
00 (Null)
14
[ ] [ ]
00 (Null)
30
[ ] [ ]
00 (Null)
15
[ ] [ ]
00 (Null)
31
[ ] [ ]
00 (Null)
16
[ ] [ ]
00 (Null)
32
[ ] [ ]
00 (Null)
Menu: 
Zone Wiring
Page 27
Zone
Type
Default
Zone
Type
Default
Wiring Types
01
[ ]
0 (Normally Closed)
17
[ ]
0 (Normally Closed)
0: Normally Closed
1: Normally Open
2: Single EOL - N/C & N/O (Burglary)
3: Single EOL - N/O (Fire)
4: Single EOL - N/C
5: Single EOL - O/C Tamper
6: Single EOL - S/C Tamper
7: Double EOL
8: Zone Doubled
02
[ ]
0 (Normally Closed)
18
[ ]
0 (Normally Closed)
03
[ ]
0 (Normally Closed)
19
[ ]
0 (Normally Closed)
04
[ ]
0 (Normally Closed)
20
[ ]
0 (Normally Closed)
05
[ ]
0 (Normally Closed)
21
[ ]
0 (Normally Closed)
06
[ ]
0 (Normally Closed)
22
[ ]
0 (Normally Closed)
07
[ ]
0 (Normally Closed)
23
[ ]
0 (Normally Closed)
08
[ ]
0 (Normally Closed)
24
[ ]
0 (Normally Closed)
09
[ ]
0 (Normally Closed)
25
[ ]
0 (Normally Closed)
10
[ ]
0 (Normally Closed)
26
[ ]
0 (Normally Closed)
11
[ ]
0 (Normally Closed)
27
[ ]
0 (Normally Closed)
12
[ ]
0 (Normally Closed)
28
[ ]
0 (Normally Closed)
13
[ ]
0 (Normally Closed)
29
[ ]
0 (Normally Closed)
14
[ ]
0 (Normally Closed)
30
[ ]
0 (Normally Closed)
15
[ ]
0 (Normally Closed)
31
[ ]
0 (Normally Closed)
16
[ ]
0 (Normally Closed)
32
[ ]
0 (Normally Closed)
Menu: 
Zone Attributes 1
Page 27
Zone
Enable
Instant
Internals
Enable Bell
Delayed Bell
Pulsed Bell
Enable
Instant
Strobe
Enable User
Chime
Enable
Transmission
Delay
Enable
Transmission
1
2
3
4
5
6
7
8
01
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
02
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
03
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
04
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
05
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
06
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
07
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
08
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
09
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
10
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
11
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
12
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
13
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]

Table of Contents

Other manuals for Texecom Premier 412