Installation Premier 412/816/832 Installation Manual
12 INS159-13
Installing Remote Keypads
Keypad Layouts
T R
+
-
4 5 6
1 2 3
7 9 08
Address DIL Switch
Tamper Switch
Piezo Sounder
Data Bus Connections
Programmable Zones 1 and 2
Speaker Output (Premier LCDL/LCDLP Only)
Programmable Output
Remote Keypad Connections
The remote keypad is connected to the data bus terminals located
at the bottom left hand side of the PCB. (See pages 8 to 10).
Remote Keypad Address
Each remote keypad must be assigned a different address using
the Address DIL switch (
). The table below shows how to set the
address:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On/Off
Off
Off
Off
2
Off
On
Off
Off
3
Off
Off
On
Off
4
Off
Off
Off
On
5
On
Off
Off
On
6
Off
On
Off
On
Keypad Zones
The Premier RKP8/16 Plus and all LCD remote keypads have two
programmable zone inputs (see page 15 for wiring details). Each
zone is also fully programmable (see page 25 for programming
details). The table below shows the zone allocation when using the
Premier RKP8/16 Plus or Premier LCD remote keypads:
Address
Premier 412
Premier 816/832
Zone 1
Zone 2
Zone 1
Zone 2
1
Zone 05
Zone 06
Zone 09
Zone 10
2
Zone 07
Zone 08
Zone 11
Zone 12
3
Zone 09
Zone 10
Zone 13
Zone 14
4
Zone 11
Zone 12
Zone 15
Zone 16
5
N/A
N/A
N/A
N/A
6
N/A
N/A
N/A
N/A
The onboard remote keypad zones are not seen by the
system until they have been enabled. To enable the onboard
keypad zones (see page 43 for details).
Keypad Output
All Premier LCD remote keypads have one programmable output,
which can be used to drive auxiliary devices such as LED’s,
sounders or relays etc. Wire as per Panel Outputs shown on page
19 (see page 47 for programming details).