Programming the Control Panel Premier 412/816/832 Installation Manual
40 INS159-13
Miscellaneous Options 3 -
Allow User Tamper Reset
On: A User can reset Tamper Alarms.
Off: A User cannot reset Tamper Alarms.
Allow Engineer Access when Armed
On: An Engineer can access the system when armed.
Off: An Engineer cannot access the system when armed.
EN50131 Options
The function of each option is described as follows:
ALL options listed below, together with Option 6 of menu 35
must be enabled if the system is to comply with EN50131.
Low Battery FOB Arming
On: An arming fob with a low battery causes a warning to be
indicated. The user must be acknowledged the warning
before arming can continue.
Off: An arming fob with a low battery arms the system.
Indicate zone Soak Test active enabled
On: A zone or zones on Soak Test being armed will cause the
“Soak Test Warning” to be displayed. The user can then
continue to arm the system or return to Day Mode.
Off: The “Soak Test Warning” message is not displayed.
Soak Test Acknowledgement enabled
On: Soak Test warnings must be acknowledged by the user.
Off: Soak Test warnings are displayed for 2 seconds before
arming continues.
Entry Stray Notification Delay
On: Entry stray notification is delayed after the alarm.
Off: Entry stray notification occurs at the time of the alarm.
Entry Timeout notifies immediately
On: Entry timeout notification is delayed after the alarm.
Off: Entry timeout notification occurs at the time of the alarm.
Expander Lost
On: A cable cut short circuit on an expander generates a Tamper
Alarm.
Off: A cable cut or short circuit on an expander generates a fault
condition.
When this option is switched on any circuits connected to
the expander will go active.
User Code Entry
A user code must be entered in 60 seconds, after every
10 invalid code entry attempts all keypads on the system
are locked out for 90 seconds. After 21invalid code
attempts a keypad tamper event will be notified.
On: A user’s code must be entered in 60 seconds.
Off: User code validity is by number of characters entered..
Mains and Battery Failures Latched
On: Mains and Battery Failures are latched and notified and must
be acknowledged before the system can be set.
Off: Mains and Battery Failures are only shown when present.