All Zone Options
This menu option allows you to program the Zone Type, Zone
Wiring, Zone Attributes 1, Zone Attributes 2, Zone Attributes 3 and
Partitions & Bypass Groups all in one sequence.
Zone Type
How the alarm system responds, when a zone is violated depends
on the zone type. The following zone types are available:
Null
A zone that is not monitored by the system, unused zones should
be programmed as Null zones.
Delay 1
This zone type is normally used for entry/exit detection. The zone
can be violated during the exit delay without causing an alarm.
Once the system/partition is armed, activation of the zone will start
the Entry Delay 1 timer for the selected partition. The user must
disarm the system before the entry timer elapses or the system will
generate an alarm.
Delay 2
Operates as Delay 1, but uses Entry Delay 2 timer for the selected
partition.
Interior Follower
This zone type is normally used for interior detection devices, such
as passive infrared sensors. The zone will not cause an alarm if
violated during the entry delay. However, if the zone is violated
before the entry delay has started, it will generate an instant alarm.
Interior Instant
This zone type is normally used for interior detection where an
instant response is required. The zone will cause an instant alarm if
it is violated when the system/partition is armed.
Perimeter Instant
This zone type is normally used for perimeter protection, windows,
patio doors etc. The zone will cause an instant alarm if it is violated
when the system/partition is armed.
Fire
This zone type is normally used for monitoring smoke detectors.
The zone will cause a unique alarm with distinctive ‘fire’ tone if it is