Specifications Premier 412/816/832 Installation Manual
78 INS159-13
6. Specifications
Control Panel
All Models Large & Small Polymer
Current
Maximum Current Available
Standby and Recharge Times
100V - 240V @ 50/60Hz; 1A
Rated Output Current @ 55°C::
Mains Terminal Block Fuse:
250Vac; 3-3.15A Slow/Medium Blow
Maximum rating of each power output (note that these are not considered to
be "independent power outputs" according to EN50131-6
Aux 12V
Siren
Network
Battery
sealed lead acid, up to 7Ah, Maximum
recharge time 72h
Battery Low Voltage Signal:
Deep Discharge protection:
F1 (2.5A) Battery Fuse
F2 (900mA) Auxiliary 12V power fuse
F3 (900mA) Siren/Bell output fuse
F4 (900mA) Network fuse
Dimensions (Small) (W x H x D)
Dimensions (Large) (W x H x D)
Maximum Current Available
Standby and Recharge Times
Rated Input:
Rated Output Current@40°C:
220V - 240V @50/60Hz; 1A
2.5A MAX
Rated Input:
Rated Output Current@40°C:
100VV - 120V @50/60Hz; 1A
2.3A MAX
Mains Terminal Block Fuse:
250Vac; 3-3.15A Slow/Medium Blow
Rated Input:
Rated Output Current@40°C:
220V - 240V @50/60Hz; 1A
2.5A MAX
Maximum rating of each power output (note that these are not considered to
be "independent power outputs" according to EN50131-6
Aux 12V
Siren
Network
Battery
sealed lead acid, up to 7Ah, Maximum
recharge time 72h
Battery Low Voltage Signal:
Deep Discharge protection:
F1 (2.5A) Battery Fuse
F2 (900mA) Auxiliary 12V power fuse
F3 (900mA) Siren/Bell output fuse
F4 (900mA) Network fuse
Up to One 12V 18Ah battery
Current Consumption
Quiescent Current:
Alarm:
Zones
Number:
EOL Resistor Value:
Panel Outputs
O/P 1 - Supervised:
O/P 2 - Supervised:
O/P 3 - 8:
1A switched to 0V
1A switched to 0V
100mA switched to 0V
Siren Output (Supervised)
Speaker Mode:
Bell Mode:
Minimum load 4
1A switched to 0V
ESL429CT
System Sensor 2100TS
Onboard Communicator
Protocols:
Pulse Format, Express Format, Fast
Format, Contact ID, SIA Level 2/3,
Pager and Mobile Phone
Dialling Formats:
REN:
Approval:
Pulse or DTMF
1
CTR21, DPT-TE-001
Non Volatile Memory Component
412, 412 Plus, 816, 816 Plus:
832
EN50136-1-1 & EN50136-2-3
The inbuilt communicator complies with the requirements of EN50136-2-3 ,
EN50136-1-1 and are suitable for use in systems designed for use with ATS
levels 1 or 2 and environmental class 1 or 2 – i.e. systems using notification
options up to and including 2B. With the PSTN functioning normally, the ATS will
comply with the required performance levels subject to the ARC being suitably
equipped.
These units may be used for Downloading, Remote Servicing or
SMS text messaging purposes in systems at ALL security
grades.
-10C to +55C
+14F to +131F
Residential/Commercial/Light
Industrial or Industrial