Premier 412/816/832 Installation Manual Specifications
INS159-13 79
Remote Keypads
ACE Type B
Electrical
Operating Voltage:
9 - 13.7VDC
Current Consumption
Nominal (model dependant):
When fully back lit:
10mA
200mA
Zone Indicators
Premier RKP4/8/16:
Premier RKP8/16 Plus:
Premier LCD/LCDL/FMK/SMK:
LED (4/8/16)
LED (8/16)
32 Character (Standard/Large)
Environmental
Operating Temperature:
-10C to +55C
+14F to +131F
Maximum Humidity:
95% non-condensing
EMC Environment:
Residential/Commercial/Light Industrial
or Industrial
Physical
Dimensions:
Premier RKP4/8/16
Premier RKP8/16 Plus/LCD/-L/P
140mm x 105mm x 35mm
145mm x 115mm x 30mm
Packed Weight:
380g
Remote Zone Expander
ACE Type B
Electrical
Operating Voltage:
9 - 13.7VDC
Current Consumption
Nominal:
In Alarm with Speaker:
35mA
180mA
Zones
Number:
EOL Resistor Value:
8
3K3
Speaker Output:
Minimum load 4
Outputs
O/P 1 & OP 2:
100mA switched to 0V
Environmental
Operating Temperature:
-10C to +55C
+14F to +131F
Maximum Humidity:
95% non-condensing
EMC Environment:
Residential/Commercial/Light
Industrial or Industrial
Physical
Dimensions:
145mm x 115mm x 30mm
Packed Weight:
260g approx.
Local Zone Expander
Electrical
Operating Voltage:
9 - 13.7VDC
Current Consumption:
35mA
Connection:
Plugs onto control panel
Zones
Number:
EOL Resistor Value:
8
3K3
Environmental
Operating Temperature:
-10C to +55C
+14F to +131F
Maximum Humidity:
95% non-condensing
EMC Environment:
Residential/Commercial/Light
Industrial or Industrial
Physical
Dimensions:
83mm x 50mm x 12mm
Packed Weight:
50g
Safety Notes
1. Only use batteries of the specified type.
2. Dispose of used batteries safely according to the
manufacturer's instructions.
3. Locate the battery inside the panel space provided.
4. This equipment is designed for dry indoor use only.
5. When replacing a fuse always observe the specified rating and
type - failure to do so is dangerous and will invalidate the
warranty. Fuses should comply with IEC 127.
6. The press-seal bag must not be stored inside the panel.
Standards
Texecom declares that this product complies with
the requirements of the following directives:
2004/108/EC EMC Directive
2006/95/EC LVD Directive
2011/65/EU RoHS Directive
The product therefore meets all the requirements
to enable it to be CE marked.
Weee Directive: 2012/19/EU (WEEE directive):
Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this
product to your local supplier upon the purchase
of equivalent new equipment, or dispose of it at
designated collection points. For more information
see: www.recyclethis.info.
This product is suitable for use in systems designed to comply
with EN 50131-1 at grade 2 and environmental class II.
EN 50131-1/3/6 Compliance
In order to comply with the requirements of EN 50131-1, EN 50131-
3 and EN 50131-6 the following programming and system
configuration must be implemented:
Menu Options 39 1-8 must all be turned ON, see page 40.
EN 50131-1 Requirements must be programmed as “Enabled”,
see page 37.
The “Permanent Keypad Status Display” option must be
programmed to Disabled” for all remote keypads, see page
42. In addition the “Courtesy Delay” timer must not be set
above 180 seconds, see page 36.
The “Partition Entry Delay” timers must not be programmed
above 45 seconds, see page 31.
The “Partition Bell Delay” timers must not be programmed
above 10 minutes, see page 31.
The Partition Bell Duration” timers must be programmed
between 2 and 15 minutes, see page 31.
“Quick Arm”, “Quick Disarm” and “Quick Bypass” option must
be programmed to “Disabled for all remote keypads, see
page 42.
The “Tamper Alarms Cause a Trouble While Disarmed” option
must be “Enabled”, see page 37.
Do not fit more than 10 unpowered detectors per zone.
Do not fit more than one non-latching powered detector per
zone.
Do not mix unpowered detectors and non-latching detectors
on a zone.
A Type W must not be used.