the partition that is in alarm. The user cannot disarm or reset
the partition if they are not assigned to it.
Off: The user can only silence alarms for partitions that are
assigned to their code.
Disable Remote Access
On: The touch-tone remote control feature is disabled for the
selected user.
Off: The touch-tone remote control feature is enabled for the
selected user.
User Options 3
User Options 3 can be enabled or disabled for a selected user so
that the level of access to the system may be altered. The following
options are available:
Allow Engineer Code Programming
On: The Access code can access User 00 (Engineer) in the
Program New Users menu (menu 80).
Off: The Access code cannot access user 00 in the Program New
Users menu.
Allow NVM Locking/Communicator Programming
On: The Access code is allowed to lock/unlock the NVM
(providing “Allow Engineer Programming” is enabled). Once
the NVM is locked the “Load Defaults” jumper pins on the
main control panel are disabled, thus preventing the panel
from being defaulted. The Access code is also allowed to
access the communicator programming menus 70 - 79.
Off: The Access code cannot lock/unlock the NVM or access
communicator programming menus 70 - 79.
Allow Engineer Programming
On: The Access code can access the Engineer programming
menus.
Off: The Access code cannot access the Engineer programming
menus.
Allow Test Call Transmission
On: The Access code can perform a test transmission to the
monitoring station (menu 92, see page 69).
Off: The Access code cannot perform a test transmission.
Allow Alarm/Fault Acknowledgement
On: The Access code can be used to acknowledge and reset
alarms and service faults. A user with this option can disarm
the system after an alarm, even if the user does not have the
"Allow Disarming" option.
Off: The Access code cannot be used to acknowledge and reset
alarms and service faults.
Allow User Programming
On: The Access code can access the user program menus (menu
90 - 98).
Off: The Access code cannot access the user program menus.
Allow User Code Programming
On: The Access code can access users 01 to 31 in the User
programming menus (menus 80 - 85).
Off: The Access code cannot access user 01 to 31 in the User
programming menus.
Local Partition Access Only
On: The Access code can only be used to arm and disarm the
partitions that are assigned to the remote keypad. For
example, if the user is assigned to all four partitions and they
use a remote keypad that is only assigned to partition 1, they
will only be permitted to arm and disarm partition 1 at that
particular remote keypad.
Off: The Access code can be used at any remote keypad (Global
access).
User Text (LCD Only)
If the system is fitted with a LCD remote keypad you can assign up
to 8 characters of text to each user. This text is used when viewing
the system Event Log, see page 77. User text is programmed in a
similar way to mobile phones. Characters are selected by pressing
the corresponding key the appropriate number of times (to select a
character on the same key, press to move the cursor along).
For details on entering text, see page 22.
Program Standard Users
This menu option allows you to add “Standard” users to the system.
The user will automatically be assigned the following options:
User Options 1: Partition 1 Access
Allow Arming
Allow Bypassing
Allow Disarming
Allow User Functions
User Options 2: Enable Open Reporting
Enable Close Reporting
Allow Global Bell/Sounder Silence
User Options 3: Allow Alarm/Fault Acknowledgement
Default ALL Users
This menu option allows you to default all Users to their factory
default settings. Before selecting this menu option you MUST link
out the “Load Defaults” pins (JP6) on the control panel PCB, see
page 8. After selecting this option, User 01(Master) is reverted to
5678 and Users 02 onwards are deleted.