EasyManua.ls Logo

Texecom Premier 412 - Protocol Options; ARC 2 Communicator Options; Fast Format Restore Channels

Texecom Premier 412
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 55
 Report Fast Format/Speech Channel 2
On: Channel 2 is reported.
Off: Channel 2 is not reported.
 Report Fast Format/Speech Channel 3
On: Channel 3 is reported.
Off: Channel 3 is not reported.
 Report Fast Format/Speech Channel 4
On: Channel 4 is reported.
Off: Channel 4 is not reported.
 Report Fast Format Channel 5
On: Channel 5 is reported.
Off: Channel 5 is not reported.
 Report Fast Format Channel 6
On: Channel 6 is reported.
Off: Channel 6 is not reported.
 Report Fast Format Channel 7
On: Channel 7 is reported.
Off: Channel 7 is not reported.
 Report Fast Format Channel 8
On: Channel 8 is reported.
Off: Channel 8 is not reported.
The channel must also be programmed to report an event,
see “Program Outputs” on page 45.
Protocol Options -
This menu option allows you to alter the operation of certain
protocol types. The Protocol Options are described as follows:
 Disable SIA Modifier Block/Enable Speech Module
On: When using SIA protocol, the area/partition modifier data
block (ri) is not transmitted. When using Fast Format protocol
the Speech Module is enabled.
Off: When using SIA protocol, the area/partition modifier data
block (ri) is transmitted. When using Fast Format protocol the
Speech Module is disabled.
 Disable Separate Events for Each Partition
On: The panel will communicate as follows:
If the event occurs in single partition, the panel will report
the event using the appropriate account number for the
partition.
If the event occurs in multiple partitions, the panel will
report the event using the appropriate account number
for the lowest partition, e.g., if the event occurs in
partitions 2, 3 and 4, the panel will report the event for
partition 2.
If the account number is not programmed for partitions
2, 3 and 4, the global (partition 1) account number is
used.
Off: The panel will communicate as follows:
If the event occurs in single partition, the panel will report
the event using the appropriate account number for the
partition.
If the event occurs in multiple partitions, the panel will
report a separate event for each partition using the
appropriate account numbers. E.g., if the event occurs in
partitions 1 and 3, the panel will report the event for
partition 1 using the account number for partition 1, then
it will report the event for partition 2 using the account
number for partition 2.
If the account number is not programmed for partitions
2, 3 and 4, the global (partition 1) account number is
used.
 Pager Terminator = * (Star)
On: When using the pager format, the panel transmits a * (star) to
terminate the pager call.
Off: When using the pager format, the panel transmits a # (hash)
to terminate the pager call.
 Send Pager Terminator Twice/SIA Text
On: When using the pager format, the panel transmits the pager
terminator (* or #) twice to terminate the pager call. If SIA
protocol is enabled, the panel will send zone/user text for
relevant events (SIA level 3).
Off: When using the pager format, the panel transmits the pager
terminator (* or #) once to terminate the pager call. If SIA
protocol is enabled, the panel does not send zone/user text
for relevant events (SIA level 2).
 Pager DTMF Tones = 500mS
On: When using the pager format, the panel transmits the pager
DTMF tones with an on time of 500mS.
Off: When using the pager format, the panel transmits the pager
DTMF tones with an on time of 80mS.
 Disable Zone Restorals
On: Zone restore events are not sent to the Alarm Receiving
Centre (even if Report Restore Events are enabled, see page
54).
Off: Zone restore events are sent to the Alarm Receiving Centre 1
(providing Report Restore Events are enabled, see page 54).
Communication Acknowledgment Tone
On: After a successful communication with the alarm receiving
centre the keypads and panel speaker will generate an
acknowledgment tone.
Off: After a successful communication the system will remain
silent.
Send via IP
On: Alarm events are sent to the ARC via the ComIP module
(TCP/IP). Only Fast Format, Contact ID and SIA protocols are
supported with this option.
Off: Alarm events are not sent via the ComIP module.
ARC 2 Communicator Options 
This option allows the on-board communicator to be configured for
Alarm Receiving Centre 2. The same options are available as for the
ARC 1 communicator options (see above).
Fast Format/Speech Restore Channels
If either ARC 1 or ARC 2 protocols are programmed as “Fast Format
(UK)”, the channels that report a restore event to the Alarm
Receiving Centre may be selected.
 Report Restore on Channel 1
On: Restore reported on channel 1.
Off: Restore not reported on channel 1.
 Report Restore on Channel 2
On: Restore reported on channel 2.
Off: Restore not reported on channel 2.

Table of Contents