Programming the Control Panel Premier 412/816/832 Installation Manual
42 INS159-13
Keypad Options 1 
The operation of Keypad Options 1 is described as follows:
 Partition 1 Operation
On: The selected keypad is assigned to Partition 1.
Off: The selected keypad is not assigned to Partition 1.
 Partition 2 Operation
On: The selected keypad is assigned to Partition 2.
Off: The selected keypad is not assigned to Partition 2.
 Partition 3 Operation (Premier 816/832 Only)
On: The selected keypad is assigned to Partition 3.
Off: The selected keypad is not assigned to Partition 3.
 Partition 4 Operation (Premier 816/832 Only)
On: The selected keypad is assigned to Partition 4.
Off: The selected keypad is not assigned to Partition 4.
 Permanent Keypad Status Display
On: The keypad status will be displayed permanently.
Off: Keypad status (not just zone status) will blank after the
courtesy timer has expired.
 Press Any Key for Display
On: If Keypad Option 1.5 (above) is selected as disabled, the
selected keypad will re-enable the display after any key press.
Off: The selected keypad display will only re-enable after a valid
Access code has been entered.
 Display Zones vs. Partitions
On: The selected keypad will use its zone lights to indicate zone
status details.
Off: The selected keypad will use its zone lights to indicate armed
status of partitions.
 Wrong Code Attempts Cause Code Tamper
On: The selected keypad will lockout key presses for 5 minutes
and will generate a code tamper alarm after 3 incorrect code
attempts (12 key presses).
Off: The keypad will accept any amount of incorrect code attempt
entries.
Keypad Options 2 
The operation of Keypad Options 2 is described as follows:
 Code Tamper Causes a Tamper Alarm
On: If a code tamper is generated by the selected keypad, the
system will give a tamper alarm response.
Off: If a code tamper is generated by the selected keypad, the
system will lock out the keypad for 5 minutes.
Keypad Options 1.8 must also be enabled.
 Keypad Activation of Fire Alarm
On: The selected keypad will generate an emergency Fire alarm if
keys and are pressed at the same time.
Off: The selected keypad will not generate an emergency Fire
alarm.
 Keypad Activation of Medical Alarm
On: The selected keypad will generate an emergency Medical
alarm if keys and are pressed at the same time.
Off: The selected keypad will not generate an emergency Medical
alarm.
 Keypad Activation of PA Alarm
On: The selected keypad will generate a Panic Alarm (Police) if
keys and are pressed at the same time.
Off: The selected keypad will not generate an emergency Panic
Alarm.
 Keypad PA Alarm is Silent
On: The selected keypad will generate a silent Panic Alarm
(Police) if keys and are pressed at the same time.
Off: The selected keypad will generate an audible Panic Alarm
(Police) if keys and are pressed at the same time.
Keypad Options 2.4 must also be enabled.
 Quick Arm with Keypad ARM Key
On: The selected keypad can be used to quick arm the system
(Access code not required).
Off: An Access code must be entered before the selected keypad
can be used to arm the system.
 Quick Disarm with Keypad DISARM Key
On: The selected keypad can be used to quick disarm the system
(Access code not required).
Off: An Access code must be entered before the selected keypad
can be used to disarm the system.
 Quick Bypass with Keypad BYPASS Key
On: The selected keypad can be used to quick bypass zones
(Access code not required).
Off: An Access code must be entered before the selected keypad
can be used to bypass zones.
Keypad Options 3 
The operation of Keypad Options 3 is described as follows:
 Fire Alarm Tones from Keypad
On: The internal sounder for the selected keypad will produce Fire
Alarm tones.
Off: Fire Alarm tones will not be produced.
 Burglary Alarm Tones from Keypad
On: The internal sounder for the selected keypad will produce
Burglary Alarm tones.
Off: Burglary Alarm tones will not be produced.
 Service Tones from Keypad
On: The internal sounder for the selected keypad will produce
Service tones.
Off: Service tones will not be produced.
 Acceptance Tones from Keypad
On: The internal sounder for the selected keypad will produce
Acceptance tones.
Off: Acceptance tones will not be produced.
 Error Tones from Keypad
On: The internal sounder for the selected keypad will produce
Error tones.
Off: Error tones will not be produced.
 Chime Tones from Keypad
On: The internal sounder for the selected keypad will produce
Chime tones.
Off: Chime tones will not be produced.
 Exit Tones from Keypad
On: The internal sounder for the selected keypad will produce Exit
tones.
Off: Exit tones will not be produced.