UDL & Digi Options Premier Elite Series Installation Manual
118 INS176-15
Non-Zone Event Types
The default Non-Zone Event codes are as follows:
No
Type
Event
Reporting Group
Contact ID
SIA
ID
22
Keypad Medical
Alarm
Priority Alarm
100
MA
Keypad No *
Restore
Restore
100
MH
Keypad No *
23
Keypad Fire
Alarm
Priority Alarm
115
FA
Keypad No *
Restore
Restore
115
FH
Keypad No *
24
Keypad Audible PA
Alarm
Priority Alarm
120
PA
Keypad No *
Restore
Restore
120
PH
Keypad No *
25
Keypad Silent PA
Alarm
Priority Alarm
122
PA
Keypad No *
Restore
Restore
122
PH
Keypad No *
26
Duress Code Alarm
Alarm
Priority Alarm
121
HA
User No
Restore
Restore -
122
HH
User No
27
Alarm Active
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
28
Bell Active
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
29
Zones Locked Out
Alarm
Alarm
570
BB
Zone No
Restore
Alarm
570
BU-
Zone No-
30
Verified Cross Zone Alarm
Alarm
Alarm
130
BV
00
Restore
Not Reported
-
-
-
31
User Code
Alarm
Not Reported
-
-
User No
Restore
Not Reported
-
-
-
32
Exit Started
Alarm
Not Reported
-
-
Keypad No
Restore
Not Reported
-
-
-
33
Exit Error (Arming Failed)
Alarm
Open/Close
457
EE
00
Restore
Open/Close
457
-
00-
34
Entry Started
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
35
Area Arm Suite
Alarm
Open/Close
-
-
Suite No 1 - 8
Restore
Open/Close
-
-
-
36
Armed with Line Fault
Alarm
Not Reported
-
-
User No
Restore
Not Reported
-
-
-
37
Open/Close (Full Arm)
Alarm
Open/Close
401
OP
User No
Restore
Open/Close
401
CL
User No
38
Open/Close (Part Arm)
Alarm
Open/Close
401
OP
User No
Restore
Open/Close
401
CL
User No
39
Auto Open/Close
Alarm
Open/Close
403
OA
00
Restore
Open/Close
403
CA
00
40
Auto Arm Deferred
Alarm
Open/Close
405
CE
User No
Restore
Open/Close
-
-
-
41
Open After Alarm (Alarm Abort)
Alarm
Open/Close
406
OR
00
Restore
Not Reported
-
-
-
42
Remote Open/Close
Alarm
Open/Close
407
OP
00
Restore
Open/Close
407
CL
00
43
Quick Arm
Alarm
Not Reported
-
-
-
Restore
Open/Close
408
CL
Keypad No *
44
Recent Closing
Alarm
Open/Close
459
CR
00
Restore
Not Reported
-
-
-
45
Reset After Alarm
Alarm
Restore
-
-
Reset ID ****
Restore
Not Reported
-
-
-
46
Power Output Fault
Alarm
Maintenance
300
YP
Device ID **
Restore
Restore
300
YQ
Device ID **
47
AC Fail
Alarm
Maintenance
301
AT
00
Restore
Restore
301
AR
00