Premier Elite 12-W/24-W/48-W Quick Start Guide
INS531-4 5
PCB Layout (48-W Shown)
1: Battery Connections
A 12V rechargeable battery must be connected to these terminals in order to
provide continuous system operation in the event of an AC Mains failure.
(protected by 1.6 Amp PTC Fuse)
2: Digicom Power & Inputs (24/48-W Only)
These terminals provide un-fused power; remote reset and line fault inputs and are
normally used for connecting a stand-alone communicator to the control panel.
3: Digicom Outputs
Outputs 1 to 8 are low current (100mA ‘-ve’ applied) and would normally be
used when connecting a stand-alone communicator to the control panel. Each
output is fully programmable.
Outputs 4-8 are not fitted on the 12-W
4: Engineers Keypad
A portable Engineers keypad can be plugged on here to allow easier access
for programming and testing.
When using a keypad as an Engineers keypad, the address
must be set to ‘10’. The keypad zones and lid tamper are not
monitored.
5: Network Data Connections
Network 1 provides connection for the keypads and zone expanders. The ‘+’
and ‘’ terminals provide power whilst the ‘T’ transmits data and ‘R’ receives
data.
6: Network Data Indicators
The red LED indicates that data is flowing out of the control panel and normally
flashes very quickly. The green LED indicates that data is flowing into the
control panel and normally flashes slowly, the green LED flashes faster as more
devices are connected.
7: Communication Ports
Com Port 1 is a serial communications port and can be used for connecting a PC
running Wintex or any supported serial device to the control panel.
Com Port 2 is a serial communications port and can be used for connecting a PC
running Wintex or any supported serial device to the control panel.
8: Auxiliary 12V Power
These terminals are for connecting devices that require 12V power (protected
by a 0.9A PTC fuse).
9: Expansion
The Expansion Port can be used for connecting a 60XiD Zone Expander or an
AV Module.
10: External Sounder Connections
These terminals are used for connecting to an external sounder unit.
11: Load Defaults Button
Press and hold this button whilst applying power to the control panel to load
the factory default settings. Press and hold this button for 7 seconds with
power already on the panel to restore just the Engineer code to the factory
setting of

.
Loading the factory defaults can take up to 60 seconds to complete.
Loading defaults will only be possible if the NVM has not been locked.
For a complete list of factory defaults, see the Premier Quick Reference
supplied on the enclosed CD.
12: Auxiliary Tamper/Fault Connections
These terminals can be used for monitoring the tamper loop of an auxiliary device.
13: Loudspeaker Connections
These terminals can be used for connecting up to one 8 or two
16loudspeakers.
14: Panel Outputs
Outputs 1 & 2 are 500mA ‘-ve’. These outputs are all fully programmable.
Output 2 is not programmable on the 12-W & 24-W
15: Zone Connections
4 Fully programmable zone inputs
16: Ricochet Network LED’s
Green LED = Data received by the expander from the panel Red LED = Data
transmitted by the expander to the panel. (The flash rate depends on the mode
and RF activity)
17: Enable 2 wire smoke (24/48-W Only)
Panel Output 1 can be used for connecting up to 10, 12V 2-Wire smoke
detectors.
18: Options Switch
Use to select the receiver functionality.
Switch 1 OFF =not used on Premier Elite 24/48-W.
Switch 2 OFF = Premier Elite 24/48-W Ricochet Mode
ON = Not Used
Switch 3 ON = Impaq Contact-W Wired Input 2 will report as Tamper (default)
OFF = input 2 will report as an Alarm.
Switch 4 OFF Walk test (see page Error! Bookmark not defined.)
19: Ricochet Eng keypad connection (24/48-W Only)
An engineer’s keypad (Premier LCD keypad and interface lead) can be
temporarily plugged onto this connector to allow system programming and
testing. Set the keypad address switches to all ON.
1
2
3
5
8
10
12
13
14
22
18
21
7
15
20
19
23
24
25
26
27
29
30
33
31
Engineer RE M
OPTIO NS
Tam per
Disab le
100mV = 1 Amp
V
F3
F4
F5
F6
F1
F8
Batt Charge
0.75A 0.3A
F2
!
BAR CODE
US E WITH
TEXECOM PSU
ONLY
F7
32
6
16
11
4
17
28

Other manuals for Texecom Premier Elite 12-W

Related product manuals