EasyManua.ls Logo

Texecom Veritas Reflex - User Manual

Texecom Veritas Reflex
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Design: Noise reduction circuits with maximum ground plane.
RF Immunity: No false alarms from 80MHz to 1GHz at 50V/m,
equivalent to a 700W uniform transmitter at 3m (10ft).
Complies with BS EN 61000-4-3 : 1997.
Electrostatic Discharge: No false alarm up to 8kV.
Complies with BS EN 61000-4-2 : 1995.
Fast Transient Immunity: No false alarm up to ±1kV.
Complies with BS EN 61000-4-4 : 1995.
High Energy Transient
Immunity: No false alarm up to ±1kV.
Complies with BS EN 61000-4-5 : 1995.
Conducted RF
Susceptibility: No false alarms at 10Vrms.
Complies with BS EN 61000-4-6 : 1996.
Conducted Emissions: Complies with EN 55022 Class B.
Radiated Emissions: Complies with EN 55022 Class B.
EMC: Independently certified to EN 50130-4 : 1996.
Pulse Count: Adjustable Pulse Count. Internal link to select.
1. PHYSICAL
INS 156-7
-35°C (-31°F) to +60°C (+140°F)
90g (3oz) approx.
-20°C (-4°F) to +55°C (+131°F)
1.5m
(4'10")
2.5m
(8'4")
3.1m
(10'0")
2.0m
(6'7")
Regulatory information
Supplier: Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4
4PW, UK.
Weee Directive: 2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points. For
more information see: www.recyclethis.info.
RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom
declares that this device does not contain lead, mercury, cadmium,
hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated
depheny ethers (PBDE) in more than the percentage specied by EU
directive 2002/95/EC, except exemptions stated in EU
directive 2002/95/EC annex.
CE Directive: 2004/108/EC (CE directive): Hereby, Texecom declares that
this device is in compliance with the essential requirements
and other relevant provisions of Directive 2004/108/EC.
Maintenance: Test yearly by the installer
Warranty: 5 year replacement warranty
Security grade: EN Grade 2 Environmental class: Class II
Standards: EN50131-2-2, PD6662:2010
Disclaimer: The Veritas Reex is not a complete alarm system, but only
its part. Therefore Texecom does not accept any responsibility or liability
for any damage that is claimed to be a result of an incorrect functioning
of the Veritas Reex detector. Texecom reserves the right to change the
specication without a prior notice.
© 1994 - 2012 Texecom Ltd
2. ENVIRONMENTAL 3. FALSE ALARM PROTECTION 4. COVERAGE & PICK-UP
5. DETECTOR WIRING & SET UP
6. MOUNTING HEIGHT & SETTINGS
1.5M/4’10
2.0M/6’7
2.5M/8’4
3.1M/10’0
-0V
+12V
ALARM
TAMPER
Mounting
Height
JP1
JP2
Instruction Manual
Veritas Reex
63mm
(2.5)
40mm
(1.6)
90mm
(3.6)
2.5mm (0.1) ABS
0.3 - 3.0m/s
LED OFF
JP2 - PULSE COUNT
1
2
3
1 - 10ft/s
DO NOT TOUCH
FAST
NORMAL
SLOW
LED ON
9-15VDC
10mA @ 12VDC
<24VDC
50mA
(N/C)
<24V
DC
50mA, 18
(N/C)
JP1 - LED
Question and Answer IconNeed help?

Do you have a question about the Texecom Veritas Reflex and is the answer not in the manual?

Texecom Veritas Reflex Specifications

General IconGeneral
BrandTexecom
ModelVeritas Reflex
CategorySecurity Sensors
LanguageEnglish

Related product manuals