BHT-412-MM-2
5-00-00
Page 24 Rev. 16 26 FEB 2013
Export Classification C, ECCN EAR99
2. Visually inspect elevators for damage and security. Check
elevator control tube for positive spring action and freedom of
movement.
Chapter 71 LEFT POWER SECTION
1. Inspect gas generator case for cracks, buckled areas, and
hot spots.
2. Inspect oil and fuel hoses and tubes for chafing, leaking,
and security.
3. Inspect electrical wiring for fraying, chafing, and security.
4. Check for proper oil level.
Chapter 71 RIGHT POWER SECTION
1. Inspect gas generator case for cracks, buckled areas, and
hot spots.
2. Inspect oil and fuel hoses and tubes for chafing, leaking,
and security.
3. Inspect electrical wiring for fraying, chafing, and security.
4. Check for proper oil level.
Chapter 71 REDUCTION GEARBOX
1. Inspect hoses and lines for chafing, leaking, and security.
2. Check oil filter impending bypass indicator button — not
extended.
3. Check for proper oil level.
Chapter 71 ENGINE AND REDUCTION GEARBOX MOUNTS
Inspect mounts for loose bearings and security.
5-5. DAILY INSPECTION — PART A (CONT)
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER